Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination.

Loading...
Thumbnail Image

Date

2021-06-06

Authors

Liu, Jing
Guo, Guo
Kurepa, Dalibor
Volpicelli, Giovanni
Sorantin, Erich
Lovrenski, Jovan
Alonso-Ojembarrena, Almudena
Hsieh, Kai-Sheng
Lodha, Abhay
Yeh, Tsu F

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Taylor & Francis
Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12-14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4-5 cm. (5) Set 1-2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2-3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to get uniform image from the near-to far-field.

Description

MeSH Terms

Humans
Infant, newborn
Infant, newborn, diseases
Lung
Pneumonia
Reproducibility of results
Ultrasonography

DeCS Terms

Enfermedades del recién nacido
Neumonía
Pulmón
Recién nacido
Reproducibilidad de los resultados
Ultrasonografía

CIE Terms

Keywords

Diagnostic image, Intensive care unit, Lung diseases, Lung ultrasound, Newborn