Publication:
Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination.

dc.contributor.authorLiu, Jing
dc.contributor.authorGuo, Guo
dc.contributor.authorKurepa, Dalibor
dc.contributor.authorVolpicelli, Giovanni
dc.contributor.authorSorantin, Erich
dc.contributor.authorLovrenski, Jovan
dc.contributor.authorAlonso-Ojembarrena, Almudena
dc.contributor.authorHsieh, Kai-Sheng
dc.contributor.authorLodha, Abhay
dc.contributor.authorYeh, Tsu F
dc.contributor.authorJagła, Mateusz
dc.contributor.authorShah, Heli
dc.contributor.authorYan, Wei
dc.contributor.authorHu, Cai-Bao
dc.contributor.authorZhou, Xiao-Guang
dc.contributor.authorGuo, Rui-Jun
dc.contributor.authorCao, Hai-Ying
dc.contributor.authorWang, Yan
dc.contributor.authorZong, Hai-Feng
dc.contributor.authorShang, Li-Li
dc.contributor.authorMa, Hai-Ran
dc.contributor.authorLiu, Ying
dc.contributor.authorFu, Wei
dc.contributor.authorShan, Rui-Yan
dc.contributor.authorQiu, Ru-Xin
dc.contributor.authorRen, Xiao-Ling
dc.contributor.authorCopetti, Roberto
dc.contributor.authorRodriguez-Fanjul, Javier
dc.contributor.authorFeletti, Francesco
dc.contributor.funderSocial Development Projects, Beijing Chaoyang District Bureau of Science, Technology and Information
dc.contributor.funderClinical Research Special Fund of Wu Jieping Medical Foundation
dc.contributor.groupSociety of Pediatrics, Asia-Pacific Health Association; the Division of Critical Ultrasound, Pediatric Society of Asia-Pacific Health Association; the Critical Ultrasound Group of Neonatal Specialty Committee, the Cross-Straits Medicine Exchange Association as well as the World Interactive Network Focused On Critical Ultrasound China Branch
dc.date.accessioned2023-02-09T11:41:08Z
dc.date.available2023-02-09T11:41:08Z
dc.date.issued2021-06-06
dc.description.abstractLung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12-14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4-5 cm. (5) Set 1-2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2-3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to get uniform image from the near-to far-field.
dc.description.versionSi
dc.identifier.citationLiu J, Guo G, Kurepa D, Volpicelli G, Sorantin E, Lovrenski J, et al. Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination. J Matern Fetal Neonatal Med. 2022 Mar;35(5):1003-1016
dc.identifier.doi10.1080/14767058.2021.1940943
dc.identifier.essn1476-4954
dc.identifier.pmid34182870
dc.identifier.unpaywallURLhttps://www.tandfonline.com/doi/pdf/10.1080/14767058.2021.1940943?needAccess=true
dc.identifier.urihttp://hdl.handle.net/10668/18051
dc.issue.number5
dc.journal.titleThe journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
dc.journal.titleabbreviationJ Matern Fetal Neonatal Med
dc.language.isoen
dc.organizationHospital Universitario Puerta del Mar
dc.organizationInstituto de Investigación e Innovación en Ciencias Biomédicas
dc.page.number1003-1016
dc.provenanceRealizada la curación de contenido 21/08/2024
dc.publisherTaylor & Francis
dc.pubmedtypeJournal Article
dc.relation.projectIDCYSF1922
dc.relation.projectIDCYSF1820
dc.relation.projectID320.6750.15072
dc.relation.publisherversionhttps://www.tandfonline.com/doi/full/10.1080/14767058.2021.1940943
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectDiagnostic image
dc.subjectIntensive care unit
dc.subjectLung diseases
dc.subjectLung ultrasound
dc.subjectNewborn
dc.subject.decsEnfermedades del recién nacido
dc.subject.decsNeumonía
dc.subject.decsPulmón
dc.subject.decsRecién nacido
dc.subject.decsReproducibilidad de los resultados
dc.subject.decsUltrasonografía
dc.subject.meshHumans
dc.subject.meshInfant, newborn
dc.subject.meshInfant, newborn, diseases
dc.subject.meshLung
dc.subject.meshPneumonia
dc.subject.meshReproducibility of results
dc.subject.meshUltrasonography
dc.titleSpecification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number35
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Liu_Specification.pdf
Size:
4.33 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Liu_Specification_MaterialSuplementario.mov
Size:
32.48 MB
Format:
Video Quicktime