Publication:
Automated Mouse Pupil Size Measurement System to Assess Locus Coeruleus Activity with a Deep Learning-Based Approach

Loading...
Thumbnail Image

Date

2021-10-26

Authors

Lara-Doña, Alejandro
Torres-Sanchez, Sonia
Priego-Torres, Blanca
Berrocoso, Esther
Sanchez-Morillo, Daniel

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI
Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Strong evidence from studies on primates and rodents shows that changes in pupil diameter may reflect neural activity in the locus coeruleus (LC). Pupillometry is the only available non-invasive technique that could be used as a reliable and easily accessible real-time biomarker of changes in the in vivo activity of the LC. However, the application of pupillometry to preclinical research in rodents is not yet fully standardized. A lack of consensus on the technical specifications of some of the components used for image recording or positioning of the animal and cameras have been recorded in recent scientific literature. In this study, a novel pupillometry system to indirectly assess, in real-time, the function of the LC in anesthetized rodents is presented. The system comprises a deep learning SOLOv2 instance-based fast segmentation framework and a platform designed to place the experimental subject, the video cameras for data acquisition, and the light source. The performance of the proposed setup was assessed and compared to other baseline methods using a validation and an external test set. In the latter, the calculated intersection over the union was 0.93 and the mean absolute percentage error was 1.89% for the selected method. The Bland-Altman analysis depicted an excellent agreement. The results confirmed a high accuracy that makes the system suitable for real-time pupil size tracking, regardless of the pupil's size, light intensity, or any features typical of the recording process in sedated mice. The framework could be used in any neurophysiological study with sedated or fixed-head animals.

Description

MeSH Terms

Medical Subject Headings::Organisms::Eukaryota::Animals
Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Rodentia::Muridae::Murinae::Mice
Medical Subject Headings::Anatomy::Sense Organs::Eye::Anterior Eye Segment::Iris::Pupil
Medical Subject Headings::Anatomy::Nervous System::Central Nervous System::Brain::Brain Stem::Mesencephalon::Locus Coeruleus
Medical Subject Headings::Psychiatry and Psychology::Behavior and Behavior Mechanisms::Psychology, Social::Group Processes::Consensus
Medical Subject Headings::Chemicals and Drugs::Biological Factors::Biological Markers::Biomarkers, Pharmacological
Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates

DeCS Terms

CIE Terms

Keywords

Pupillometry, Locus coeruleus, Pupil size, Image processing, Deep learning, Machine learning, Pupila, Anisocoria, Procesamiento de imagen asistido por computador, Aprendizaje profundo, Aprendizaje automático

Citation

Lara-Doña A, Torres-Sanchez S, Priego-Torres B, Berrocoso E, Sanchez-Morillo D. Automated Mouse Pupil Size Measurement System to Assess Locus Coeruleus Activity with a Deep Learning-Based Approach. Sensors. 2021 Oct 26;21(21):7106