Publication:
Optimizing the Limit of Detection of Waveguide-Based Interferometric Biosensor Devices

Loading...
Thumbnail Image

Date

2019-08-23

Authors

Leuermann, Jonas
Fernández-Gavela, Adrián
Torres-Cubillo, Antonia
Postigo, Sergio
Sánchez-Postigo, Alejandro
Lechuga, Laura M.
Halir, Robert
Molina-Fernández, Íñigo

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI
Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Waveguide-based photonic sensors provide a unique combination of high sensitivity, compact size and label-free, multiplexed operation. Interferometric configurations furthermore enable a simple, fixed-wavelength read-out making them particularly suitable for low-cost diagnostic and monitoring devices. Their limit of detection, i.e., the lowest analyte concentration that can be reliably observed, mainly depends on the sensors response to small refractive index changes, and the noise in the read-out system. While enhancements in the sensors response have been extensively studied, noise optimization has received much less attention. Here we show that order-of-magnitude enhancements in the limit of detection can be achieved through systematic noise reduction, and demonstrate a limit of detection of ∼ 10−8RIU with a silicon nitride sensor operating at telecom wavelengths.

Description

MeSH Terms

Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Molecular Probe Techniques::Biosensing Techniques
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Interferometry
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Epidemiologic Methods::Statistics as Topic::Sensitivity and Specificity::Limit of Detection
Medical Subject Headings::Technology and Food and Beverages::Technology, Industry, and Agriculture::Engineering::Optics and Photonics
Medical Subject Headings::Chemicals and Drugs::Inorganic Chemicals::Silicon Compounds

DeCS Terms

CIE Terms

Keywords

Biosensors, Coherent detection, Interferometer, Limit of detection, Silicon photonics, Técnicas biosensibles, Límite de detección

Citation