Publication: Fast Analysis of Caffeic Acid-Related Molecules in Instant Coffee by Reusable Sonogel-Carbon Electrodes.
dc.contributor.author | Pigani, Laura | |
dc.contributor.author | Rioli, Cristina | |
dc.contributor.author | Zanfrognini, Barbara | |
dc.contributor.author | Garcia-Guzman, Juan Jose | |
dc.contributor.author | Palacios-Santander, Jose Maria | |
dc.contributor.author | Cubillana-Aguilera, Laura Maria | |
dc.date.accessioned | 2023-05-03T14:22:15Z | |
dc.date.available | 2023-05-03T14:22:15Z | |
dc.date.issued | 2022-10-29 | |
dc.description.abstract | Reusable Sonogel-Carbon electrodes containing carbon black (SNGC-CB) have been used for the electrochemical analysis of caffeic acid (CA) in real matrices. Measurements were firstly performed in standard solutions, in which SNGC-CB electrodes allowed the electrochemical determination of CA with high sensitivity and low limit of detection, equal to 0.76 μM. The presence of CB nanostructures in the formulation led to improved performances with respect to pristine SNGC electrodes. Then, measurements were performed in four instant coffees of different brands. A comparison between the results obtained by electrochemical, chromatographic and spectroscopic methods showed that SBGC-CB electrodes represent a simple and economic tool for the rapid assessment of caffeic acid-related molecules in instant coffees. | |
dc.description.version | Si | |
dc.identifier.citation | Pigani L, Rioli C, Zanfrognini B, García-Guzmán JJ, Palacios-Santander JM, Cubillana-Aguilera LM. Fast Analysis of Caffeic Acid-Related Molecules in Instant Coffee by Reusable Sonogel-Carbon Electrodes. Sensors (Basel). 2022 Nov 3;22(21):8448 | |
dc.identifier.doi | 10.3390/s22218448 | |
dc.identifier.essn | 1424-8220 | |
dc.identifier.pmc | PMC9655352 | |
dc.identifier.pmid | 36366146 | |
dc.identifier.pubmedURL | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655352/pdf | |
dc.identifier.unpaywallURL | https://www.mdpi.com/1424-8220/22/21/8448/pdf?version=1667460640 | |
dc.identifier.uri | http://hdl.handle.net/10668/21573 | |
dc.issue.number | 21 | |
dc.journal.title | Sensors (Basel, Switzerland) | |
dc.language.iso | en | |
dc.organization | Hospital Universitario Puerta del Mar | |
dc.organization | Instituto de Investigación e Innovación en Ciencias Biomédicas | |
dc.page.number | 10 | |
dc.provenance | Realizada la curación de contenido 02/09/2024 | |
dc.publisher | MDPI | |
dc.pubmedtype | Journal Article | |
dc.relation.publisherversion | https://www.mdpi.com/1424-8220/22/21/8448 | |
dc.rights | Attribution 4.0 International | |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Sonogel–Carbon electrode | |
dc.subject | Caffeic acid | |
dc.subject | Carbon black | |
dc.subject | Coffee | |
dc.subject | Differential pulse voltammetry | |
dc.subject | Electrochemical sensor | |
dc.subject | Polyphenols | |
dc.subject.decs | Café | |
dc.subject.decs | Carbono | |
dc.subject.decs | Electrodos | |
dc.subject.decs | Límite de detección | |
dc.subject.decs | Técnicas electroquímicas | |
dc.subject.decs | Ácidos cafeicos | |
dc.subject.mesh | Carbon | |
dc.subject.mesh | Coffee | |
dc.subject.mesh | Electrodes | |
dc.subject.mesh | Caffeic Acids | |
dc.subject.mesh | Electrochemical Techniques | |
dc.subject.mesh | Limit of Detection | |
dc.title | Fast Analysis of Caffeic Acid-Related Molecules in Instant Coffee by Reusable Sonogel-Carbon Electrodes. | |
dc.type | research article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 22 | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1