Publication: A resistance-sensing mechanical injector for the precise delivery of liquids to target tissue.
dc.contributor.author | Chitnis, Girish D | |
dc.contributor.author | Verma, Mohan K S | |
dc.contributor.author | Lamazouade, Julien | |
dc.contributor.author | Gonzalez-Andrades, Miguel | |
dc.contributor.author | Yang, Kisuk | |
dc.contributor.author | Dergham, Ali | |
dc.contributor.author | Jones, Peter Anthony | |
dc.contributor.author | Mead, Benjamin E | |
dc.contributor.author | Cruzat, Andrea | |
dc.contributor.author | Tong, Zhixiang | |
dc.contributor.author | Martyn, Keir | |
dc.contributor.author | Solanki, Aniruddh | |
dc.contributor.author | Landon-Brace, Natalie | |
dc.contributor.author | Karp, Jeffrey M | |
dc.date.accessioned | 2023-01-25T13:38:53Z | |
dc.date.available | 2023-01-25T13:38:53Z | |
dc.date.issued | 2019-02-25 | |
dc.description.abstract | The precision of the delivery of therapeutics to the desired injection site by syringes and hollow needles typically depends on the operator. Here, we introduce a highly sensitive, completely mechanical and cost-effective injector for targeting tissue reliably and precisely. As the operator pushes the syringe plunger, the injector senses the loss-of-resistance on encountering a softer tissue or a cavity, stops advancing the needle and delivers the payload. We demonstrate that the injector can reliably deliver liquids to the suprachoroidal space-a challenging injection site that provides access to the back of the eye-for a wide range of eye sizes, scleral thicknesses and intraocular pressures, and target sites relevant for epidural injections, subcutaneous injections and intraperitoneal access. The design of this simple and effective injector can be adapted for a broad variety of clinical applications. | |
dc.description.sponsorship | Funding for this research was provided by the R01HL095722 to JMK. Animal experiments were funded through Boston-KPro research fund to MGA and A.C. We would like to thank Dr. Yookyung Jung and Prof. Charles P. Lin for the use of intravital microscope, H. Greg Lin and Harvard’s Center for Nanoscale Systems for use of microCT system, and Kathleen Cormier and the Hope Babette Tang Histology Facility at the Koch Institute at MIT for performing histology sections | |
dc.identifier.citation | Chitnis GD, Verma MKS, Lamazouade J, Gonzalez-Andrades M, Yang K, Dergham A, et al. A resistance-sensing mechanical injector for the precise delivery of liquids to target tissue. Nat Biomed Eng. 2019 Aug;3(8):621-631 | |
dc.identifier.doi | 10.1038/s41551-019-0350-2 | |
dc.identifier.essn | 2157-846X | |
dc.identifier.pmc | PMC6688633 | |
dc.identifier.pmid | 31391590 | |
dc.identifier.pubmedURL | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6688633/pdf | |
dc.identifier.unpaywallURL | https://europepmc.org/articles/pmc6688633?pdf=render | |
dc.identifier.uri | http://hdl.handle.net/10668/14376 | |
dc.issue.number | 8 | |
dc.journal.title | Nature biomedical engineering | |
dc.journal.titleabbreviation | Nat Biomed Eng | |
dc.language.iso | en | |
dc.organization | Hospital Universitario Reina Sofía | |
dc.organization | Instituto Maimónides de Investigación Biomédica de Córdoba-IMIBIC | |
dc.page.number | 621-631 | |
dc.provenance | Realizada la curación de contenido 13/08/2024 | |
dc.provenance | Realizada la curación de contenido 13/08/2024 | |
dc.publisher | Nature Publishing Group | |
dc.pubmedtype | Journal Article | |
dc.pubmedtype | Research Support, N.I.H., Extramural | |
dc.pubmedtype | Research Support, Non-U.S. Gov't | |
dc.relation.publisherversion | https://www.nature.com/articles/s41551-019-0350-2 | |
dc.rights.accessRights | open access | |
dc.subject | Injections, intraperitoneal | |
dc.subject | Injections, subcutaneous | |
dc.subject | Needles | |
dc.subject | Rabbits | |
dc.subject | Syringes | |
dc.subject | Wounds and injuries | |
dc.subject.decs | Bombas de infusión | |
dc.subject.decs | Diseño de equipo | |
dc.subject.decs | Inyecciones | |
dc.subject.decs | Inyecciones epidurales | |
dc.subject.decs | Ojo | |
dc.subject.decs | Sistemas de liberación de medicamentos | |
dc.subject.mesh | Animals | |
dc.subject.mesh | Drug delivery systems | |
dc.subject.mesh | Equipment design | |
dc.subject.mesh | Eye | |
dc.subject.mesh | Humans | |
dc.subject.mesh | Infusion pumps | |
dc.subject.mesh | Injections | |
dc.subject.mesh | Injections, epidural | |
dc.title | A resistance-sensing mechanical injector for the precise delivery of liquids to target tissue. | |
dc.type | research article | |
dc.type.hasVersion | AM | |
dc.volume.number | 3 | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- RISalud_Accesorestringido.pdf
- Size:
- 93.39 KB
- Format:
- Adobe Portable Document Format