Publication:
Normative reference values for hand grip dynamometry in Spain. Association with lean mass.

dc.contributor.authorSánchez Torralvo, Francisco José
dc.contributor.authorPorras, Nuria
dc.contributor.authorAbuín Fernández, José
dc.contributor.authorGarcía Torres, Francisca
dc.contributor.authorTapia, María José
dc.contributor.authorLima, Fuensanta
dc.contributor.authorSoriguer, Federico
dc.contributor.authorGonzalo, Montserrat
dc.contributor.authorRojo Martínez, Gemma
dc.contributor.authorOlveira, Gabriel
dc.date.accessioned2023-01-25T10:05:27Z
dc.date.available2023-01-25T10:05:27Z
dc.date.issued2018-01-16
dc.description.abstractThe objective of this study was to establish reference values for hand grip strength, compare the results obtained with Collin and Jamar type dynamometers and determine their association with anthropometric and lean mass measurements. This cross-sectional population-based study was undertaken in Pizarra (Málaga, Spain). The grip strength of the dominant hand was measured using Collin and Jamar dynamometers. Skinfolds (triceps, abdominal, biceps of dominant arm and subscapular) were measured, and body composition was estimated. Eight hundred seventeen adults randomly selected from the census were recruited. Dynamometry reference values are presented for the dominant hand, by gender and age groups. No determinations could be made with the Collin dynamometer in 69 women due to the difficulty in grasping the dynamometer. We found significant positive correlations between the measurements with Jamar and Collin dynamometers (r = 0.782; p Dynamometry reference values in the Spanish population are presented. We recommend the use of the Jamar type dynamometer versus the Collin type dynamometer. Hand grip dynamometry is associated with lean mass, which confirms its usefulness in nutritional assessment.
dc.identifier.doi10.20960/nh.1052
dc.identifier.essn1699-5198
dc.identifier.pmid29565156
dc.identifier.unpaywallURLhttps://doi.org/10.20960/nh.1052
dc.identifier.urihttp://hdl.handle.net/10668/12264
dc.issue.number1
dc.journal.titleNutricion hospitalaria
dc.journal.titleabbreviationNutr Hosp
dc.language.isoen
dc.organizationHospital Universitario Regional de Málaga
dc.organizationInstituto de Investigación Biomédica de Málaga-IBIMA
dc.page.number98-103
dc.pubmedtypeJournal Article
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subject.meshAdolescent
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshBody Composition
dc.subject.meshCross-Sectional Studies
dc.subject.meshFemale
dc.subject.meshHand Strength
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle Aged
dc.subject.meshMuscle Strength Dynamometer
dc.subject.meshReference Values
dc.subject.meshSkinfold Thickness
dc.subject.meshSpain
dc.subject.meshYoung Adult
dc.titleNormative reference values for hand grip dynamometry in Spain. Association with lean mass.
dc.title.alternativeValores de normalidad de dinamometría de mano en España. Relación con la masa magra.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number35
dspace.entity.typePublication

Files