Publication: Influence of reduction in the elution times on HPLC glycohaemoglobin results
dc.contributor.author | Leon-Justel, Antonio | |
dc.contributor.author | Santotoribio, Jose D. | |
dc.contributor.author | Dominguez-Pascual, Inmaculada | |
dc.contributor.author | Delgado, Ana L. | |
dc.contributor.author | Macias, Carlos | |
dc.contributor.author | Herrera, Maria T. | |
dc.contributor.author | Leal, Alfonso | |
dc.contributor.author | Mangas, Miguel A. | |
dc.contributor.author | Acosta, Domingo | |
dc.contributor.author | Guerrero, J.M. | |
dc.contributor.authoraffiliation | [Leon-Justel,A; Santotoribio,JD; Dominguez-Pascual,I; Delgado,AL; Macias,C; Herrera,MT; Guerrero,JM] Department of Clinical Biochemistry, Virgen del Rocío University Hospital, IBIS/CSIC/University of Seville, Seville, Spain. | |
dc.contributor.authoraffiliation | [Leal,A; Mangas,MA; Acosta,D] Clinical Management Unit for Endocrinology and Nutrition, Virgen del Rocío University Hospital, IBIS/CSIC/University of Seville, Seville, Spain. | |
dc.date.accessioned | 2024-01-30T14:14:33Z | |
dc.date.available | 2024-01-30T14:14:33Z | |
dc.date.issued | 2009-07-16 | |
dc.description.abstract | Objectives To compare HPLC methods with short and long elution times for HbA1c measurement in blood. Methods Comparison between G7-Tosoh (1.2 min); Bio-Rad-Variant-II-Turbo (1.3 min) and Arkray-HA-8160 (2.9 min). Results Passing–Bablok regression equations were: Y = 0.17 + 0.96X; Y = − 0.39 + 1.01X; Y = − 0.40 + 1.0X and the means of the differences using Bland–Altman Plot were 0.02; − 0.34; 0.32 for HA-8160/G7-Tosoh, HA-8160/Variant-II-Turbo and G7-Tosoh/Variant-II-Turbo, respectively. Conclusions Faster elution methods had no problems on reproducibility of results obtained by slower elution methods. | |
dc.description.version | Yes | |
dc.identifier.citation | Leon-Justel A, Santotoribio JD, Dominguez-Pascual I, Delgado AL, Macias C, Herrera MT, et al. Influence of reduction in the elution times on HPLC glycohaemoglobin results. Clin Biochem. 2009 Oct;42(15):1582-4. | |
dc.identifier.doi | 10.1016/j.clinbiochem.2009.07.003 | |
dc.identifier.issn | 1873-2933 | |
dc.identifier.pmid | 19615990 | |
dc.identifier.uri | https://hdl.handle.net/10668/23207 | |
dc.issue.number | 15 | |
dc.journal.title | Clinical Biochemistry | |
dc.language.iso | en | |
dc.page.number | 3 p. | |
dc.publisher | Elsevier | |
dc.relation.publisherversion | https://www.sciencedirect.com/science/article/pii/S0009912009002963?via%3Dihub | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
dc.rights.accessRights | restricted access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Cromatografía líquida de alta presión | |
dc.subject | Sangre | |
dc.subject.decs | Cromatografía líquida de alta presión | |
dc.subject.decs | Sangre | |
dc.title | Influence of reduction in the elution times on HPLC glycohaemoglobin results | |
dc.type | research article | |
dc.volume.number | 42 | |
dspace.entity.type | Publication |