Publication:
Intolerancia a tornillo interferencial tibial. Una rara complicación en la Cirugía de reconstrucción del ligamento cruzado anterior

Loading...
Thumbnail Image

Date

2016-11

Authors

López-Lobato, R
Fornell-Pérez, S
Serrano-Toledano, D
García-Mendoza, A
Barrena-Sánchez, P
Puente-González, A.I
Domecq-Fernández de Bobadilla, G

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Sociedad Andaluza de Traumatología y Ortopedia
Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Introducción: Se presenta una serie de casos de pacientes que han desarrollado bultoma, secreción y dolor pretibial tras la reconstrucción del LCA fijado con tornillos reabsorbibles (HA-PLLA [Hidroxiapatita- ácido L-poliláctico]). Método: Se revisan de manera retrospectiva todas las reconstrucciones de LCA realizadas entre 2008 y 2014 para identificar las complicaciones relacionadas con el sistema de fijación bioabsorbible. Durante ese periodo de 6 años se realizaron 620 reconstrucciones de LCA usando el tornillo bioabsorbible (HA-PLLA) para la fijación tibial del injerto tetrafascicular de isquiotibiales. Resultados: Nueve pacientes (1,45%) con un rango de edad de 29,8 (19-44 años), presentaron el periodo postoperatorio dolor, tumoración y secreción pretibial en la zona de inserción del tornillo. Todos presentaron marcadores inflamatorios normales. Todos los pacientes requirieron desbridamiento quirúrgico, y retirada de los restos del tornillo y de los tejidos reactivos. Se evidenció infección en 4 cultivos intraoperatorios. La anatomía patológica reveló restos detríticos birrefringentes en el citoplasma de los macrófagos. La retirada de los restos del tornillo y el desbridamiento y curetaje del túnel, supuso la recuperación completa de todos los pacientes de nuestra serie. Conclusiones: La tumoración pre-tibial como respuesta biológica adversa, debe considerarse como una posible complicación en la reconstrucción del LCA. Se aprecia una incidencia de 1,45% de reacción pretibial tras el uso de tornillos reabsorbibles (HA-PLLA) en tibia proximal en la reconstrucción de LCA.
Background: We report a series of cases that presented as pre-tibial cyst, swelling and pain following anterior cruciate ligament (ACL) reconstruction using bioabsorble fixation devices (HA-PLLA). Methods: All ACL reconstructions were done between 2008 and 2014 reviewed retropectively to identify complications related to bioabsorbable fixation devices. During this period of 6 years, 620 ACL reconstructions were performed using the bioabsorbable screw (HA-PLLA) for tibial fixation of the quadrupled hamstring autograft. Results: Nine patients (1,45%) with mean age of 29,8 (19-44) years, presented in the post-operative period, pre-tibial pain, cyst and swelling in tibial screw site. All of them had normal inflammatory markers. All of these patients underwent surgical debridement, which revealed remnants of screw and reactive material. There was evidence of infection in 4 intra-operative specimen cultures. Histopathology revealed detritic birefringent remains in macrophages cytoplasm. Removal of screw debris and curettage of the tunnel resulted in complete recovery of all patients in our series. Conclusions: Pre-tibial cyst as an adverse biological response should be considered as a possible complication in ACL reconstruction. We report a 1,45% of pre-tibial reaction in patients undergoing ACL reconstruction with bio-absorbable (HAPLLA) interference screw fixation for the proximal tibia.

Description

MeSH Terms

Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Absorbable Implants
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Therapeutics::Orthopedic Procedures::Anterior Cruciate Ligament Reconstruction
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Surgical Equipment::Surgical Fixation Devices::Orthopedic Fixation Devices::Internal Fixators::Bone Screws
Medical Subject Headings::Diseases::Pathological Conditions, Signs and Symptoms::Pathological Conditions, Anatomical::Cysts
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Debridement
Medical Subject Headings::Anatomy::Musculoskeletal System::Skeleton::Bone and Bones::Bones of Lower Extremity::Leg Bones::Tibia

DeCS Terms

CIE Terms

Keywords

Reconstrucción LCA, Tornillo bioabsorbible, Quiste pretibial, ACL reconstruction, Bioabsorbable screw, Pre-tibial cyst

Citation

López-Lobato R, Fornell-Pérez S, Serrano-Toledano D, García-Mendoza A, Barrena-Sánchez P, Puente-González AI, et al. Intolerancia a tornillo interferencial tibial. Una rara complicación en la Cirugía de reconstrucción del ligamento cruzado anterior. Rev. S. And. Traum. y Ort., 2015; 33(3/4): 49-56