TY - JOUR AU - Hidalgo-López, José A AU - Sánchez-Durán, José A AU - Oballe-Peinado, Óscar PY - 2020 DO - 10.3390/s20092596 UR - http://hdl.handle.net/10668/15504 T2 - Sensors (Basel, Switzerland) AB - Direct Interface Circuits (DICs) carry out resistive sensor readings using a resistance-to-time-to-digital conversion without the need for analog-to-digital converters. The main advantage of this approach is the simplicity involved in designing a DIC,... LA - en KW - calibration methods KW - direct interface circuits KW - error analysis KW - interface sensor KW - resistive sensor KW - time-based measurement TI - Reducing Measurement Time in Direct Interface Circuits for Resistive Sensor Readout. TY - research article VL - 20 ER -