RT Journal Article T1 [Do COPD patients lie about their smoking habit?]. T2 ¿Mienten los pacientes con EPOC sobre su hábito tabáquico? A1 Almadana Pacheco, Virginia A1 Benito Bernáldez, Cristina A1 Luque Crespo, Estefanía A1 Perera Louvier, Rafael A1 Rodríguez Fernández, Julio César A1 Valido Morales, Agustín S K1 COPD K1 Cooximetry K1 Cooximetría K1 EPOC K1 Entrevista K1 Ex-smoker K1 Exfumadores K1 Interview K1 Smoking K1 Tabaquismo AB To determine the deception rate or concordance between the interview on smoking and cooximetry in COPD patients from a monographic consultation. Prospective observational study to evaluate the concordance between the values of cooximetry and the response to a clinical interview on smoking. COPD monographic consultation, Pneumology, Seville. Patients with a confirmed diagnosis of COPD in any degree. Clinical interview and measurement of carbon monoxide by cooximetry. Cooximetry values, responses on smoking, sociodemographic variables. n: 169. 107 patients presented values less than or equal to 6 ppm compared to 62 with values greater than 6 ppm, determining a prevalence of active smoking of 36.7%. The deception rate was 19.5% of the total sample (24.3% of all those who claimed not to smoke), with a Cohen kappa of 0.48 and p In spite of our attempts to make patients stop smoking, a considerable deception rate was found in our consultation; higher among women, recent ex-smokers or in the process of abandonment, so it would be essential to incorporate objective measures such as the cooximeter in the approach of this type of patient. YR 2020 FD 2020-07-30 LK http://hdl.handle.net/10668/16035 UL http://hdl.handle.net/10668/16035 LA es DS RISalud RD Apr 4, 2025