High-Accuracy Readout Electronics for Piezoresistive Tactile Sensors.

No Thumbnail Available

Date

2017-11-01

Authors

Hidalgo-López, José A
Oballe-Peinado, Óscar
Castellanos-Ramos, Julián
Sánchez-Durán, José A
Fernández-Ramos, Raquel
Vidal-Verdú, Fernando

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

The typical layout in a piezoresistive tactile sensor arranges individual sensors to form an array with M rows and N columns. While this layout reduces the wiring involved, it does not allow the values of the sensor resistors to be measured individually due to the appearance of crosstalk caused by the nonidealities of the array reading circuits. In this paper, two reading methods that minimize errors resulting from this phenomenon are assessed by designing an electronic system for array reading, and the results are compared to those obtained using the traditional method, obviating the nonidealities of the reading circuit. The different models were compared by testing the system with an array of discrete resistors. The system was later connected to a tactile sensor with 8 × 7 taxels.

Description

MeSH Terms

DeCS Terms

CIE Terms

Keywords

parallel analog data acquisition, piezoresistive tactile sensors, resistive sensor arrays

Citation