Primary stability and PES/WES evaluation for immediate implants in the aesthetic zone: a pilot clinical double-blind randomized study.

dc.contributor.authorSanchez-Perez, Arturo
dc.contributor.authorNicolas-Silvente, Ana I
dc.contributor.authorSanchez-Matas, Carmen
dc.contributor.authorMolina-García, Silvia
dc.contributor.authorNavarro-Cuellar, Carlos
dc.contributor.authorRomanos, Georgios E
dc.date.accessioned2025-01-07T15:36:45Z
dc.date.available2025-01-07T15:36:45Z
dc.date.issued2021-10-08
dc.description.abstractThe use of immediate implants in the aesthetic area is a technique widely used in modern implantology. The characteristics of the patient, the implant, and the surgical procedure used may influence the final results. The aim was to assess whether the implant design affects primary (P.S.) and secondary stability (S.S.), bone level (B.L.), and PES/WES evaluation. Twenty implants with two different designs (n = 10) were immediately placed and randomly located in the upper anterior maxilla with no grafting material. Implant-Stability-Quotient (ISQ), B.L., and Pink-Esthetic-Score/White-Esthetic-Score (PES/WES) were evaluated. Shapiro-Wilk normality test was performed to determine the sample normality, as the data did not follow a normal distribution, the Wilcoxon-Mann-Whitney test was applied (p 
dc.identifier.doi10.1038/s41598-021-99218-8
dc.identifier.essn2045-2322
dc.identifier.pmcPMC8501062
dc.identifier.pmid34625591
dc.identifier.pubmedURLhttps://pmc.ncbi.nlm.nih.gov/articles/PMC8501062/pdf
dc.identifier.unpaywallURLhttps://www.nature.com/articles/s41598-021-99218-8.pdf
dc.identifier.urihttps://hdl.handle.net/10668/27271
dc.issue.number1
dc.journal.titleScientific reports
dc.journal.titleabbreviationSci Rep
dc.language.isoen
dc.organizationSAS - Hospital Universitario Virgen del Rocío
dc.page.number20024
dc.pubmedtypeJournal Article
dc.pubmedtypeRandomized Controlled Trial
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.meshAged
dc.subject.meshAged, 80 and over
dc.subject.meshDental Implantation
dc.subject.meshDental Implants
dc.subject.meshDouble-Blind Method
dc.subject.meshEsthetics, Dental
dc.subject.meshFemale
dc.subject.meshFollow-Up Studies
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle Aged
dc.subject.meshOsseointegration
dc.subject.meshRisk Factors
dc.subject.meshTooth Socket
dc.subject.meshTreatment Outcome
dc.titlePrimary stability and PES/WES evaluation for immediate implants in the aesthetic zone: a pilot clinical double-blind randomized study.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number11

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
PMC8501062.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format