Inter-Day Reliability of Resting Metabolic Rate and Maximal Fat Oxidation during Exercise in Healthy Men Using the Ergostik Gas Analyzer.

dc.contributor.authorRobles-González, Lidia
dc.contributor.authorGutiérrez-Hellín, Jorge
dc.contributor.authorAguilar-Navarro, Millán
dc.contributor.authorRuiz-Moreno, Carlos
dc.contributor.authorMuñoz, Alejandro
dc.contributor.authorDel-Coso, Juan
dc.contributor.authorR Ruiz, Jonatan
dc.contributor.authorAmaro-Gahete, Francisco J
dc.date.accessioned2025-01-07T12:31:48Z
dc.date.available2025-01-07T12:31:48Z
dc.date.issued2021-11-29
dc.description.abstractThe attainment of high inter-day reliability is crucial to determine changes in resting metabolic rate (RMR), respiratory exchange ratio (RER), maximal fat oxidation during exercise (MFO) and the intensity that elicits MFO (Fatmax) after an intervention. This study aimed to analyze the inter-day reliability of RMR, RER, MFO and Fatmax in healthy adults using the Ergostik gas analyzer. Fourteen healthy men (age: 24.4 ± 5.0 years, maximum oxygen uptake (VO2max): 47.5 ± 11.9 mL/kg/min) participated in a repeated-measures study. The study consisted of two identical experimental trials (Day 1 and Day 2) in which the participants underwent an indirect calorimetry assessment at resting and during an incremental exercise test. Stoichiometric equations were used to calculate energy expenditure and substrate oxidation rates. There were no significant differences when comparing RMR (1999.3 ± 273.9 vs. 1955.7 ± 362.6 kcal/day, p = 0.389), RER (0.87 ± 0.05 vs. 0.89 ± 0.05, p = 0.143), MFO (0.32 ± 0.20 vs. 0.31 ± 0.20 g/min, p = 0.776) and Fatmax (45.0 ± 8.6 vs. 46.4 ± 8.4% VO2max, p = 0.435) values in Day 1 vs. Day 2. The inter-day coefficient of variation for RMR, RER, MFO and Fatmax were 4.85 ± 5.48%, 3.22 ± 3.14%, 7.78 ± 5.51%, and 6.51 ± 8.04%, respectively. In summary, the current results show a good inter-day reliability when RMR, RER, MFO and Fatmax are determined in healthy men using the Ergostik gas analyzer.
dc.identifier.doi10.3390/nu13124308
dc.identifier.essn2072-6643
dc.identifier.pmcPMC8708346
dc.identifier.pmid34959860
dc.identifier.pubmedURLhttps://pmc.ncbi.nlm.nih.gov/articles/PMC8708346/pdf
dc.identifier.unpaywallURLhttps://www.mdpi.com/2072-6643/13/12/4308/pdf?version=1638173593
dc.identifier.urihttps://hdl.handle.net/10668/24688
dc.issue.number12
dc.journal.titleNutrients
dc.journal.titleabbreviationNutrients
dc.language.isoen
dc.organizationEscuela Andaluza de Salud Pública
dc.organizationInstituto de Investigación Biosanitaria de Granada (ibs.GRANADA)
dc.pubmedtypeClinical Trial
dc.pubmedtypeJournal Article
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectFatmax
dc.subjectMFO
dc.subjectRER
dc.subjectRMR
dc.subjectmetabolic rate
dc.subjectreproducibility
dc.subject.meshAdipose Tissue
dc.subject.meshAdult
dc.subject.meshBasal Metabolism
dc.subject.meshBlood Gas Analysis
dc.subject.meshCalorimetry, Indirect
dc.subject.meshEnergy Metabolism
dc.subject.meshExercise
dc.subject.meshExercise Test
dc.subject.meshHealthy Volunteers
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshOxidation-Reduction
dc.subject.meshOxygen
dc.subject.meshOxygen Consumption
dc.subject.meshReproducibility of Results
dc.subject.meshYoung Adult
dc.titleInter-Day Reliability of Resting Metabolic Rate and Maximal Fat Oxidation during Exercise in Healthy Men Using the Ergostik Gas Analyzer.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number13

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
PMC8708346.pdf
Size:
866.21 KB
Format:
Adobe Portable Document Format