Multicenter experience with a second- generation fully-retrievable and repositionable transcatheter aortic valve

dc.contributor.authorGemma, Daniele
dc.contributor.authorMoreno, Raul
dc.contributor.authorLarman, Mariano
dc.contributor.authorTeles, Rui Campante
dc.contributor.authorPatricio, Lino
dc.contributor.authorMolina, Eduardo
dc.contributor.authorRibeiro, Vasco Gama
dc.contributor.authorDel Blanco, Bruno Garcia
dc.contributor.authorGranado, Roque Arana
dc.contributor.authorValero, Santiago Jimenez
dc.contributor.authorGaleote, Guillermo
dc.contributor.authorHernandez, Harold
dc.contributor.authorIrazusta Cordoba, Francisco Javier
dc.contributor.authorSerra, Vicenc
dc.contributor.authorLopez-Sendon, Jose Luis
dc.contributor.authoraffiliation[Gemma, Daniele] Hosp Luz, Unidad Hemodinam & Cardiol Intervencionista, Madrid, Spain
dc.contributor.authoraffiliation[Moreno, Raul] Hosp Univ La Paz, CIBERCV, IDIPAZ, Unidad Hemodinam Cardiologia Intervencionista, Madrid, Spain
dc.contributor.authoraffiliation[Valero, Santiago Jimenez] Hosp Univ La Paz, CIBERCV, IDIPAZ, Unidad Hemodinam Cardiologia Intervencionista, Madrid, Spain
dc.contributor.authoraffiliation[Lopez-Sendon, Jose Luis] Hosp Univ La Paz, CIBERCV, IDIPAZ, Unidad Hemodinam Cardiologia Intervencionista, Madrid, Spain
dc.contributor.authoraffiliation[Larman, Mariano] Policlin Gipuzkoa, Unidad Hemodinam & Cardiol Intervencionista, San Sebastian, Spain
dc.contributor.authoraffiliation[Teles, Rui Campante] Hosp Santa Cruz, Unidad Hemodinam & Cardiol Intervencionista, Lisbon, Portugal
dc.contributor.authoraffiliation[Patricio, Lino] Ctr Hosp Lisboa Cent, Unidad Hemodinam & Cardiol Intervencionista, Lisbon, Portugal
dc.contributor.authoraffiliation[Molina, Eduardo] Hosp Virgen Ias Nieves, Unidad Hemodinam & Cardiol Intervencionista, Granada, Spain
dc.contributor.authoraffiliation[Ribeiro, Vasco Gama] Ctr Hosp Vila Nova Gaia, Unidad Hemodinam & Cardiol Intervencionista, Oporto, Portugal
dc.contributor.authoraffiliation[Del Blanco, Bruno Garcia] Hosp Univ Vall dHebron, Unidad Hemodinam & Cardiol Intervencionista, Barcelona, Spain
dc.contributor.authoraffiliation[Serra, Vicenc] Hosp Univ Vall dHebron, Unidad Hemodinam & Cardiol Intervencionista, Barcelona, Spain
dc.contributor.authoraffiliation[Granado, Roque Arana] Hosp Puerta Mar, Unidad Hemodinam & Cardiol Intervencionista, Cadiz, Spain
dc.date.accessioned2025-01-07T14:21:07Z
dc.date.available2025-01-07T14:21:07Z
dc.date.issued2020-04-01
dc.description.abstractIntroduction and objectives: The Lotus Valve device (Boston Scientific) is a second-generation fully-retrievable and repositionable transcatheter aortic valve. We report the initial multicenter experience with the Lotus valve in the management of patients with severe aortic stenosis. Methods: Observational study that described the short and long-term results of implanting the Lotus valve in 8 Spanish and Portuguese centers from March 2014 through April 2016. Results: The study included 102 patients (mean age 80.4 +/- 6.1 years; STS score 5.2% +/- 3.3%) with severe symptomatic aortic stenosis (mean aortic valve area 0.66 +/- 0.17 cm(2), aortic gradients 74.3 / 45.6 mmHg). The valve was successfully implanted in 100 patients (98%), with significant improvement in both the peak and mean aortic valve gradients and with only one patient showing moderate paravalvular regurgitation. Upon hospital discharge, mortality rate was 3.9% while the stroke rate was 2.9%. No cases of valve embolization, ectopic valve deployment or additional valve implantation (valve-in-valve) were seen. Thirty-three patients (32.3%) received a permanent pacemaker. Conclusions: The Lotus Valve System is effective and safe for the management of patients with severe symptomatic aortic stenosis. In particular, considering the low rate of periprosthetic regurgitation and lack of complications like embolization or ectopic valve deployment; however at the expense of a high pacemaker implantation rate.
dc.identifier.doi10.24875/RECICE.M19000092
dc.identifier.essn2604-7276
dc.identifier.issn2604-7306
dc.identifier.unpaywallURLhttps://doi.org/10.24875/recice.m19000092
dc.identifier.urihttps://hdl.handle.net/10668/26312
dc.identifier.wosID908946200006
dc.issue.number2
dc.journal.titleRec-interventional cardiology
dc.journal.titleabbreviationRec-interv. cardiol.
dc.language.isoen
dc.organizationSAS - Hospital Universitario Virgen de las Nieves
dc.page.number90-97
dc.publisherPermanyer publ
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectTranscatheter Aortic Valve.
dc.subjectAortic Stenosis
dc.titleMulticenter experience with a second- generation fully-retrievable and repositionable transcatheter aortic valve
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number2
dc.wostypeArticle

Files