Abstract

Placing the left ventricular (LV) lead in a viable segment with the latest mechanical activation (vSOLA) may be associated with optimal cardiac resynchronization therapy (CRT) response. We assessed the role of gated SPECT myocardial perfusion imaging (gSPECT MPI) in predicting clinical outcomes at 6 months in patients submitted to CRT. Ten centers from 8 countries enrolled 195 consecutive patients. All underwent gSPECT MPI before and 6 months after CRT. The procedure was performed as per current guidelines, the operators being unaware of gSPECT MPI results. Regional LV dyssynchrony (Phase SD) and vSOLA were automatically determined using a 17 segment model. The lead was considered on-target if placed in vSOLA. The primary outcome was improvement in ≥1 of the following: ≥1 NYHA class, left ventricular ejection fraction (LVEF) by ≥5%, reduction in end-systolic volume by ≥15%, and ≥5 points in Minnesota Living With Heart Failure Questionnaire (MLHFQ). Sixteen patients died before the follow-up gSPECT MPI. The primary outcome occurred in 152 out of 179 (84.9%) cases. Mean change in LV phase standard deviation (PSD) at 6 months was 10.5°. Baseline dyssynchrony was not associated with the primary outcome. However, change in LV PSD from baseline was associated with the primary outcome (OR 1.04, 95% CI 1.01-1.07, P = .007). Change in LV PSD had an AUC of 0.78 (0.66-0.90) for the primary outcome. Improvement in LV PSD of 4° resulted in the highest positive likelihood ratio of 7.4 for a favorable outcome. In 23% of the patients, the CRT lead was placed in the vSOLA, and in 42% in either this segment or in a segment within 10° of it. On-target lead placement was not significantly associated with the primary outcome (OR 1.53, 95% CI 0.71-3.28). LV dyssynchrony improvement by gSPECT MPI, but not on-target lead placement, predicts clinical outcomes in patients undergoing CRT.

Description

MeSH Terms

Aged
Cardiac Resynchronization Therapy
Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography
Cohort Studies
Female
Heart Failure
Humans
Male
Middle Aged
Myocardial Perfusion Imaging
Predictive Value of Tests
Treatment Outcome

DeCS Terms

CIE Terms

Keywords

Single-photon emission computed tomography, cardiac resynchronization therapy, dyssynchrony, phase analysis

Citation