Publication:
Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing.

dc.contributor.authorNaranjo-Hernández, David
dc.contributor.authorTalaminos-Barroso, Alejandro
dc.contributor.authorReina-Tosina, Javier
dc.contributor.authorRoa, Laura M
dc.contributor.authorBarbarov-Rostan, Gerardo
dc.contributor.authorCejudo-Ramos, Pilar
dc.contributor.authorMárquez-Martín, Eduardo
dc.contributor.authorOrtega-Ruiz, Francisco
dc.date.accessioned2023-01-25T10:20:43Z
dc.date.available2023-01-25T10:20:43Z
dc.date.issued2018-07-03
dc.description.abstractIn this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (p
dc.identifier.doi10.3390/s18072144
dc.identifier.essn1424-8220
dc.identifier.pmcPMC6068602
dc.identifier.pmid29970861
dc.identifier.pubmedURLhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068602/pdf
dc.identifier.unpaywallURLhttps://www.mdpi.com/1424-8220/18/7/2144/pdf?version=1530622935
dc.identifier.urihttp://hdl.handle.net/10668/12671
dc.issue.number7
dc.journal.titleSensors (Basel, Switzerland)
dc.journal.titleabbreviationSensors (Basel)
dc.language.isoen
dc.organizationHospital Universitario Virgen del Rocío
dc.pubmedtypeJournal Article
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectChronic Obstructive Pulmonary Disease (COPD)
dc.subjectInternet of Medical Things (IoMT)
dc.subjectcapacitive sensing
dc.subjectrespiratory rate
dc.subjectrespiratory rehabilitation
dc.subject.meshAdult
dc.subject.meshElectric Capacitance
dc.subject.meshFemale
dc.subject.meshHumans
dc.subject.meshInternet
dc.subject.meshMale
dc.subject.meshMonitoring, Physiologic
dc.subject.meshPulmonary Disease, Chronic Obstructive
dc.subject.meshRespiratory Rate
dc.subject.meshWearable Electronic Devices
dc.titleSmart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number18
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PMC6068602.pdf
Size:
4.21 MB
Format:
Adobe Portable Document Format