Publication:
İnter-rater and intra-rater reliability of the extended TUG test in elderly participants.

dc.contributor.authorBedoya-Belmonte, Juan José
dc.contributor.authorRodríguez-González, María Del Mar
dc.contributor.authorGonzález-Sánchez, Manuel
dc.contributor.authorPitarch, Jose Miguel Barreda
dc.contributor.authorGalán-Mercant, Alejandro
dc.contributor.authorCuesta-Vargas, Antonio I
dc.date.accessioned2023-02-08T14:41:17Z
dc.date.available2023-02-08T14:41:17Z
dc.date.issued2020-02-13
dc.description.abstractTo analyse the reliability, variance and execution time of the Extended Timed Up and Go (Extended TUG) test in three age groups of elderly participants (G1: 55-64 years; G2: 65-74 years; G3: 75-85 years). An analytical cross-sectional study of 114 recruited participants (63 women) of average age 70.17 (± 7.3) years was undertaken. Each participant performed the Extended TUG three consecutive times, with a rest break between tests of 120 s. Both the intragroup and intergroup reliability of the measurements in the Extended TUG were analysed. The reliability of the Extended TUG test is excellent for the first and second decades but drops down to good for the third decade. Specifically, intragroup reliability ranged from 0.784 for G3 to 0.977 for G1 (G2 = 0.858). Intergroup reliability, compared with intragroup reliability, was slightly lower, ranging between 0.779 for G3 and 0.972 for G1 (G2 = 0.853). The reliability of the Extended TUG test progressively decreases with increasing age, being excellent for the younger age groups and good for the oldest age group.
dc.identifier.doi10.1186/s12877-020-1460-0
dc.identifier.essn1471-2318
dc.identifier.pmcPMC7020600
dc.identifier.pmid32054448
dc.identifier.pubmedURLhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7020600/pdf
dc.identifier.unpaywallURLhttps://doi.org/10.1186/s12877-020-1460-0
dc.identifier.urihttp://hdl.handle.net/10668/15104
dc.issue.number1
dc.journal.titleBMC geriatrics
dc.journal.titleabbreviationBMC Geriatr
dc.language.isoen
dc.organizationIBIMA
dc.page.number56
dc.pubmedtypeJournal Article
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.meshAged
dc.subject.meshCross-Sectional Studies
dc.subject.meshFemale
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle Aged
dc.subject.meshPhysical Therapy Modalities
dc.subject.meshReproducibility of Results
dc.titleİnter-rater and intra-rater reliability of the extended TUG test in elderly participants.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number20
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PMC7020600.pdf
Size:
523.7 KB
Format:
Adobe Portable Document Format