Publication:
Reducing Measurement Time in Direct Interface Circuits for Resistive Sensor Readout.

dc.contributor.authorHidalgo-López, José A
dc.contributor.authorSánchez-Durán, José A
dc.contributor.authorOballe-Peinado, Óscar
dc.date.accessioned2023-02-08T14:48:55Z
dc.date.available2023-02-08T14:48:55Z
dc.date.issued2020-05-02
dc.description.abstractDirect Interface Circuits (DICs) carry out resistive sensor readings using a resistance-to-time-to-digital conversion without the need for analog-to-digital converters. The main advantage of this approach is the simplicity involved in designing a DIC, which only requires some additional resistors and a capacitor in order to perform the conversion. The main drawback is the time needed for this conversion, which is given by the sum of up to three capacitor charge times and their associated discharge times. This article presents a modification of the most widely used estimation method in a resistive DIC, which is known as the Two-Point Calibration Method (TPCM), in which a single additional programmable digital device pin in the DIC and one extra measurement in each discharge cycle, made without slowing down the cycle, allow charge times to be reduced more than 20-fold to values around 2 µs. The new method designed to achieve this reduction only penalizes relative errors with a small increase of between 0.2% and 0.3% for most values in the tested resistance range.
dc.identifier.doi10.3390/s20092596
dc.identifier.essn1424-8220
dc.identifier.pmcPMC7249154
dc.identifier.pmid32370230
dc.identifier.pubmedURLhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7249154/pdf
dc.identifier.unpaywallURLhttps://www.mdpi.com/1424-8220/20/9/2596/pdf?version=1588416166
dc.identifier.urihttp://hdl.handle.net/10668/15504
dc.issue.number9
dc.journal.titleSensors (Basel, Switzerland)
dc.journal.titleabbreviationSensors (Basel)
dc.language.isoen
dc.organizationIBIMA
dc.pubmedtypeJournal Article
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectcalibration methods
dc.subjectdirect interface circuits
dc.subjecterror analysis
dc.subjectinterface sensor
dc.subjectresistive sensor
dc.subjecttime-based measurement
dc.titleReducing Measurement Time in Direct Interface Circuits for Resistive Sensor Readout.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number20
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PMC7249154.pdf
Size:
3.1 MB
Format:
Adobe Portable Document Format