Publication:
Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials

dc.contributor.authorAlfonso, Fernando
dc.contributor.authorPerez-Vizcayno, Maria Jose
dc.contributor.authordel Blanco, Bruno Garcia
dc.contributor.authorGarcia-Touchard, Arturo
dc.contributor.authorLopez-Minguez, Jose-Ramon
dc.contributor.authorMasotti, Monica
dc.contributor.authorZueco, Javier
dc.contributor.authorMelgares, Rafael
dc.contributor.authorMainar, Vicente
dc.contributor.authorMoreno, Raul
dc.contributor.authorDominguez, Antonio
dc.contributor.authorSanchis, Juan
dc.contributor.authorBethencourt, Armando
dc.contributor.authorMoreu, Jose
dc.contributor.authorCequier, Angel
dc.contributor.authorMarti, Vicens
dc.contributor.authorOtaegui, Imanol
dc.contributor.authorBastante, Teresa
dc.contributor.authorGonzalo, Nieves
dc.contributor.authorJimenez-Quevedo, Pilar
dc.contributor.authorCardenas, Alberto
dc.contributor.authorFernandez, Cristina
dc.contributor.authorSpanish Soc Cardiology
dc.contributor.authoraffiliation[Alfonso, Fernando] Hosp Univ La Princesa, Madrid, Spain
dc.contributor.authoraffiliation[Bastante, Teresa] Hosp Univ La Princesa, Madrid, Spain
dc.contributor.authoraffiliation[Perez-Vizcayno, Maria Jose] Hosp Univ Clin San Carlos, Madrid, Spain
dc.contributor.authoraffiliation[Gonzalo, Nieves] Hosp Univ Clin San Carlos, Madrid, Spain
dc.contributor.authoraffiliation[Jimenez-Quevedo, Pilar] Hosp Univ Clin San Carlos, Madrid, Spain
dc.contributor.authoraffiliation[Cardenas, Alberto] Hosp Univ Clin San Carlos, Madrid, Spain
dc.contributor.authoraffiliation[Fernandez, Cristina] Hosp Univ Clin San Carlos, Madrid, Spain
dc.contributor.authoraffiliation[Perez-Vizcayno, Maria Jose] Fdn Interhosp Invest Cardiovasc, Madrid, Spain
dc.contributor.authoraffiliation[del Blanco, Bruno Garcia] Hosp Univ Vall dHebron, Barcelona, Spain
dc.contributor.authoraffiliation[Otaegui, Imanol] Hosp Univ Vall dHebron, Barcelona, Spain
dc.contributor.authoraffiliation[Garcia-Touchard, Arturo] Hosp Univ Puerta de Hierro Majadahonda, Madrid, Spain
dc.contributor.authoraffiliation[Lopez-Minguez, Jose-Ramon] Hosp Univ Infanta Cristina, Badajoz, Spain
dc.contributor.authoraffiliation[Masotti, Monica] Hosp Univ Clin Barcelona, Barcelona, Spain
dc.contributor.authoraffiliation[Zueco, Javier] Hosp Univ Marques de Valdecilla, Santander, Spain
dc.contributor.authoraffiliation[Melgares, Rafael] Hosp Univ Virgen de las Nieves, Granada, Spain
dc.contributor.authoraffiliation[Mainar, Vicente] Hosp Univ Alicante, Javea, Spain
dc.contributor.authoraffiliation[Moreno, Raul] Hosp Univ La Paz, Madrid, Spain
dc.contributor.authoraffiliation[Dominguez, Antonio] Hosp Univ Virgen de la Victoria, Malaga, Spain
dc.contributor.authoraffiliation[Sanchis, Juan] Hosp Univ Clin Valencia, Valencia, Spain
dc.contributor.authoraffiliation[Bethencourt, Armando] Hosp Univ Son Espases, Palma De Mallorca, Spain
dc.contributor.authoraffiliation[Moreu, Jose] Hosp Univ Virgen de la Salud Toledo, Toledo, OH USA
dc.contributor.authoraffiliation[Cequier, Angel] Hosp Univ Bellvitge, Barcelona, Spain
dc.contributor.authoraffiliation[Marti, Vicens] Hosp Univ San Pau, Barcelona, Spain
dc.contributor.authoraffiliation[Cardenas, Alberto] USFQ, Sch Med, Quito, Ecuador
dc.date.accessioned2023-02-12T02:21:59Z
dc.date.available2023-02-12T02:21:59Z
dc.date.issued2016-07-01
dc.description.abstractBackground-Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled.Methods and Results-A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22 +/- 0.5 versus 2.38 +/- 0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03 +/- 0.7 versus 2.36 +/- 0.6 mm, P
dc.identifier.doi10.1161/CIRCINTERVENTIONS.115.003479
dc.identifier.essn1941-7632
dc.identifier.issn1941-7640
dc.identifier.unpaywallURLhttps://www.ahajournals.org/doi/pdf/10.1161/CIRCINTERVENTIONS.115.003479
dc.identifier.urihttp://hdl.handle.net/10668/19086
dc.identifier.wosID380607800006
dc.issue.number7
dc.journal.titleCirculation-cardiovascular interventions
dc.journal.titleabbreviationCirc.-cardiovasc. interv.
dc.language.isoen
dc.organizationHospital Universitario Virgen de la Victoria
dc.publisherLippincott williams & wilkins
dc.rights.accessRightsopen access
dc.subjectangiography
dc.subjectdrug-eluting stents
dc.subjecteverolimus
dc.subjectmetal
dc.subjectregression analysis
dc.subjectrestenosis
dc.subjectCoated balloon angioplasty
dc.subjectEfficacy
dc.subjectNeoatherosclerosis
dc.subjectImplantation
dc.subjectMulticenter
dc.subjectOutcomes
dc.subjectSafety
dc.titleEverolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number9
dc.wostypeArticle
dspace.entity.typePublication

Files