Publication:
General-purpose passive wireless point-of-care platform based on smartphone.

dc.contributor.authorEscobedo, Pablo
dc.contributor.authorErenas, Miguel M
dc.contributor.authorMartínez-Olmos, Antonio
dc.contributor.authorCarvajal, Miguel A
dc.contributor.authorGonzalez-Chocano, Sara
dc.contributor.authorCapitán-Vallvey, Luis Fermín
dc.contributor.authorPalma, Alberto J
dc.date.accessioned2023-01-25T13:34:41Z
dc.date.available2023-01-25T13:34:41Z
dc.date.issued2019-05-30
dc.description.abstractA versatile, compact and low-cost analytical platform has been designed, tested and validated to be used in the point-of-care settings. This passive measurement system is powered and complemented by a standard smartphone including a programmed application for measurement configuration and data processing as well as wireless results sharing. Electrochemical and electrochemiluminescence analytical techniques can be configured and realized by this platform that employs standard screen-printed electrodes for the sample managing and off-the-shelf electronic components. The power, electrical and optical signal processing have been studied in depth. The system can harvest energy up to 22.5 mW, set up a voltage in the range of ±1.15 V, and measure potentials in a range of 600 mV with an uncertainty of 1 mV, and current from 2 μA to 0.75 mA with a resolution of 1.1 μA. Moreover, standard tests have been performed to the platform consisting of amperometric, potentiometric, cyclic voltammetry and electrochemiluminescent analytical techniques, showing excellent agreement with a reference instrument. Finally, our design has also been applied to glucose, pH and H2O2 determinations, providing the full analytical parameters which are in very good agreement with the reference instrument results. Ranges (0.065-0.75 M, 0.62-100 mM and 3-9 pH units for glucose, H2O2 and pH, respectively) and limits of detection (0.024 M and 0.03 mM for glucose and H2O2, respectively) make this low-cost platform (
dc.identifier.doi10.1016/j.bios.2019.111360
dc.identifier.essn1873-4235
dc.identifier.pmid31176114
dc.identifier.unpaywallURLhttps://digibug.ugr.es/bitstream/10481/56492/1/Escobedo%20et%20al..%202019.%20General-purpose%20passive%20wireless%20point%e2%80%93of%e2%80%93care%20platform%20based%20on%20smartphone.pdf
dc.identifier.urihttp://hdl.handle.net/10668/14089
dc.journal.titleBiosensors & bioelectronics
dc.journal.titleabbreviationBiosens Bioelectron
dc.language.isoen
dc.organizationIBS
dc.page.number111360
dc.pubmedtypeJournal Article
dc.rights.accessRightsopen access
dc.subjectElectrochemical techniques
dc.subjectElectrochemiluminescence
dc.subjectEnergy harvesting
dc.subjectNear-field communication
dc.subjectPassive point-of-care platform
dc.subjectSmartphone
dc.subject.meshBiosensing Techniques
dc.subject.meshEquipment Design
dc.subject.meshGlucose
dc.subject.meshHumans
dc.subject.meshHydrogen Peroxide
dc.subject.meshHydrogen-Ion Concentration
dc.subject.meshLimit of Detection
dc.subject.meshPoint-of-Care Systems
dc.subject.meshSmartphone
dc.subject.meshWireless Technology
dc.titleGeneral-purpose passive wireless point-of-care platform based on smartphone.
dc.typeresearch article
dc.type.hasVersionAM
dc.volume.number141
dspace.entity.typePublication

Files