Publication: Intrapericardial pacemaker in a 2-kilogram newborn.
dc.contributor.author | Gil-Jaurena, Juan-Miguel | |
dc.contributor.author | Castillo, Rafael | |
dc.contributor.author | Rubio, Lorena | |
dc.contributor.authoraffiliation | [Gil-Jaurena,JM; Castillo,R; Rubio,L] Pediatric Cardiac Surgery, Hospital Carlos Haya, Málaga, Spain. | es |
dc.date.accessioned | 2013-10-02T10:34:18Z | |
dc.date.available | 2013-10-02T10:34:18Z | |
dc.date.issued | 2012-04-04 | |
dc.description | Case Reports; Journal Article; | es |
dc.description.abstract | A 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis. | es |
dc.description.embargo | 2013-08 | |
dc.description.version | Yes | es |
dc.identifier.citation | Gil-Jaurena JM, Castillo R, Rubio L. Intrapericardial pacemaker in a 2-kilogram newborn. Cardiol Young. 2012; 22(4):459-60 | es |
dc.identifier.doi | 10.1017/S1047951112000455 | |
dc.identifier.essn | 1467-1107 | |
dc.identifier.issn | 1047-9511 | |
dc.identifier.pmid | 23066539 | |
dc.identifier.uri | http://hdl.handle.net/10668/1306 | |
dc.journal.title | Cardiology in the Young | |
dc.language.iso | en | |
dc.publisher | Cambridge University Press | es |
dc.relation.publisherversion | http://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=8633070&fulltextType=XX&fileId=S1047951112000455 | es |
dc.rights.accessRights | open access | |
dc.subject | Intrapericardial | es |
dc.subject | Pacemaker | es |
dc.subject | Child | es |
dc.subject | Pared abdominal | es |
dc.subject | Marcapasos artificial | es |
dc.subject | Bloqueo cardíaco | es |
dc.subject | Recién nacido | es |
dc.subject | Pericardiectomía | es |
dc.subject | Femenino | es |
dc.subject.mesh | Medical Subject Headings::Check Tags::Female | es |
dc.subject.mesh | Medical Subject Headings::Diseases::Cardiovascular Diseases::Heart Diseases::Arrhythmias, Cardiac::Heart Block | es |
dc.subject.mesh | Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans | es |
dc.subject.mesh | Medical Subject Headings::Named Groups::Persons::Age Groups::Infant::Infant, Newborn | es |
dc.subject.mesh | Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Electrical Equipment and Supplies::Electrodes::Pacemaker, Artificial | es |
dc.subject.mesh | Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Cardiac Surgical Procedures::Pericardiectomy | es |
dc.subject.mesh | Medical Subject Headings::Diseases::Pathological Conditions, Signs and Symptoms::Pathologic Processes::Postoperative Complications::Prosthesis Failure | es |
dc.subject.mesh | Medical Subject Headings::Anatomy::Body Regions::Torso::Abdomen::Abdominal Wall | es |
dc.title | Intrapericardial pacemaker in a 2-kilogram newborn. | es |
dc.type | research article | |
dc.type.hasVersion | VoR | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- GilJM_IntrapericardialPacemaker.pdf
- Size:
- 56.68 KB
- Format:
- Adobe Portable Document Format
- Description:
- Artículo publicado