Publication:
Intrapericardial pacemaker in a 2-kilogram newborn.

dc.contributor.authorGil-Jaurena, Juan-Miguel
dc.contributor.authorCastillo, Rafael
dc.contributor.authorRubio, Lorena
dc.contributor.authoraffiliation[Gil-Jaurena,JM; Castillo,R; Rubio,L] Pediatric Cardiac Surgery, Hospital Carlos Haya, Málaga, Spain.es
dc.date.accessioned2013-10-02T10:34:18Z
dc.date.available2013-10-02T10:34:18Z
dc.date.issued2012-04-04
dc.descriptionCase Reports; Journal Article;es
dc.description.abstractA 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis.es
dc.description.embargo2013-08
dc.description.versionYeses
dc.identifier.citationGil-Jaurena JM, Castillo R, Rubio L. Intrapericardial pacemaker in a 2-kilogram newborn. Cardiol Young. 2012; 22(4):459-60es
dc.identifier.doi10.1017/S1047951112000455
dc.identifier.essn1467-1107
dc.identifier.issn1047-9511
dc.identifier.pmid23066539
dc.identifier.urihttp://hdl.handle.net/10668/1306
dc.journal.titleCardiology in the Young
dc.language.isoen
dc.publisherCambridge University Presses
dc.relation.publisherversionhttp://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=8633070&fulltextType=XX&fileId=S1047951112000455es
dc.rights.accessRightsopen access
dc.subjectIntrapericardiales
dc.subjectPacemakeres
dc.subjectChildes
dc.subjectPared abdominales
dc.subjectMarcapasos artificiales
dc.subjectBloqueo cardíacoes
dc.subjectRecién nacidoes
dc.subjectPericardiectomíaes
dc.subjectFemeninoes
dc.subject.meshMedical Subject Headings::Check Tags::Femalees
dc.subject.meshMedical Subject Headings::Diseases::Cardiovascular Diseases::Heart Diseases::Arrhythmias, Cardiac::Heart Blockes
dc.subject.meshMedical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humanses
dc.subject.meshMedical Subject Headings::Named Groups::Persons::Age Groups::Infant::Infant, Newbornes
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Electrical Equipment and Supplies::Electrodes::Pacemaker, Artificiales
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Cardiac Surgical Procedures::Pericardiectomyes
dc.subject.meshMedical Subject Headings::Diseases::Pathological Conditions, Signs and Symptoms::Pathologic Processes::Postoperative Complications::Prosthesis Failurees
dc.subject.meshMedical Subject Headings::Anatomy::Body Regions::Torso::Abdomen::Abdominal Walles
dc.titleIntrapericardial pacemaker in a 2-kilogram newborn.es
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
GilJM_IntrapericardialPacemaker.pdf
Size:
56.68 KB
Format:
Adobe Portable Document Format
Description:
Artículo publicado