Publication:
CIEDE2000 lightness, chroma and hue human gingiva thresholds.

dc.contributor.authorPerez, Maria M
dc.contributor.authorCarrillo-Perez, Francisco
dc.contributor.authorTejada-Casado, Maria
dc.contributor.authorRuiz-Lopez, Javier
dc.contributor.authorBenavides-Reyes, Cristina
dc.contributor.authorHerrera, Luis Javier
dc.contributor.funderJunta de Andalucía
dc.contributor.funderSpanish Ministry of Science, Innovation and Universities
dc.contributor.funderUniversity of Granada
dc.date.accessioned2023-05-03T15:03:43Z
dc.date.available2023-05-03T15:03:43Z
dc.date.issued2022-07-02
dc.description.abstractTo determine the visual 50:50% perceptibility and acceptability CIEDE2000 lightness, chroma and hue human gingiva thresholds. A psychophysical experiment based on visual assessments of simulated images of human gingiva on a calibrated display was performed. A 20-obsever panel (dentists and laypersons; n=10) evaluated three subsets of simulated human gingiva: lightness subset (|ΔL'/ΔE00|≥ 0.98); chroma subset (|ΔC'/ΔE00|≥ 0.98) and hue subset (|ΔH'/ΔE00|≥ 0.96) using ΔE00 The 50:50% PT were ΔL' = 0.74 (95% confidence interval (CI) 0.39-1.09); ΔC' = 1.10 (95% CI 0.57-1.46); ΔH' = 2.40 (95% CI 1.66->3.85). The 50:50% AT were ΔL' = 2.57 (95% CI 2.00-3.06); ΔC' = 2.70 (95% CI 2.19-3.38). AT ΔH' may be considered no computable. PT values were statistically significant among the three metric differences (p ≤ 0.05). No difference was found between observers for PT values. Statistically differences in perceptual limit were found among hue, lightness and chroma for human gingiva. Thus, the observers seem to show lower sensitivity for changes in hue (ΔH') than in chroma (ΔC') and in lightness (ΔL') in the gingiva color space. PT and AT for lightness, chroma and hue specific for human gingiva should be used when evaluating natural gingiva, pink gingival shade guides or pink materials, since the thresholds of perception and acceptability for teeth are not suitable.
dc.description.sponsorshipecial thanks to the observers who took part in this study. The authors acknowledge funding support from research projects P20-00200 from I+D+I Junta de Andalucía, PGC2018-101904-A-100 and RTI2018-101674-B-I00 from the Spanish Ministry of Science, Innovation and Universities, A.TEP.280.UGR18 from University of Granada. Funding for open access charge: Universidad de Granada / CBUA.
dc.description.versionSi
dc.identifier.citationPérez MM, Carrillo-Perez F, Tejada-Casado M, Ruiz-López J, Benavides-Reyes C, Herrera LJ. CIEDE2000 lightness, chroma and hue human gingiva thresholds. J Dent. 2022 Sep;124:104213.
dc.identifier.doi10.1016/j.jdent.2022.104213
dc.identifier.essn1879-176X
dc.identifier.pmid35793761
dc.identifier.unpaywallURLhttps://doi.org/10.1016/j.jdent.2022.104213
dc.identifier.urihttp://hdl.handle.net/10668/22300
dc.journal.titleJournal of dentistry
dc.journal.titleabbreviationJ Dent
dc.language.isoen
dc.organizationInstituto de Investigación Biosanitaria de Granada (ibs.GRANADA)
dc.page.number6
dc.provenanceRealizada la curación de contenido 27/08/2024
dc.publisherElsevier Ltd
dc.pubmedtypeJournal Article
dc.pubmedtypeResearch Support, Non-U.S. Gov't
dc.relation.projectIDP20-00200
dc.relation.projectIDPGC2018-101904-A-100
dc.relation.projectIDRTI2018-101674-B-I00
dc.relation.projectIDA.TEP.280.UGR18
dc.relation.publisherversionhttps://linkinghub.elsevier.com/retrieve/pii/S0300-5712(22)00269-X
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCIEDE2000
dc.subjectChroma
dc.subjectHue
dc.subjectHuman gingiva
dc.subjectLightness
dc.subjectVisual thresholds
dc.subject.decsColor
dc.subject.decsDiente
dc.subject.decsEncía
dc.subject.decsHumanos
dc.subject.meshColor
dc.subject.meshGingiva
dc.subject.meshHumans
dc.subject.meshTooth
dc.titleCIEDE2000 lightness, chroma and hue human gingiva thresholds.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number124
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Perez_CIEDE2000Lightness.pdf
Size:
1015.32 KB
Format:
Adobe Portable Document Format