dc.description.abstractThe quality correction factor [Formula: see text] for electron beams was calculated for three thimble ionization chambers, namely, NE2571, NE2571A and NE2581A. The Monte Carlo code PENELOPE was used to estimate the overall correction factor fc,Q of these chambers for electron beams with nominal energies ranging between 6 and 22MeV, corresponding to a Varian Clinac 2100 C/D. A 60Co beam was used as reference quality Q0. Also eight monoenergetic electron beams reproducing the quality index R50 of the Clinac beams were considered. The [Formula: see text] factors were calculated as the ratio between fc,Q and [Formula: see text] . Those obtained for the NE2571 ionization chamber show a nice agreement with those calculated by Muir and Rogers with EGSnrc. As it occurred to other ionization chambers analyzed in previous works, the [Formula: see text] factors found for the monoenergetic beams are larger (smaller) than those corresponding to the Clinac beams at low (high) R50 values, the differences being slightly above 0.5%. Finally, the [Formula: see text] factors obtained in the case of the NE2571A chamber are systematically ∼0.5% below those of its predecessor chamber, the NE2571.
dc.identifier.doi10.1016/j.ejmp.2017.05.053
dc.identifier.essn1724-191X
dc.identifier.pmid28610700
dc.identifier.unpaywallURLhttp://dspace.ucuenca.edu.ec/bitstream/123456789/29280/1/documento.pdf
dc.identifier.urihttp://hdl.handle.net/10668/11299
dc.journal.titlePhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
dc.journal.titleabbreviationPhys Med
dc.language.isoen
dc.organizationIBS
dc.page.number76-80
dc.pubmedtypeJournal Article
dc.rights.accessRightsopen access
dc.subjectcorrection factors
dc.subjectElectron beams
dc.subjectNE2571
dc.subjectNE2571A
dc.subjectNE2581A
dc.subjectPENELOPE
dc.subject.meshElectrons
dc.subject.meshMonte Carlo Method
dc.subject.meshRadiometry
dc.subject.meshRelative Biological Effectiveness
dc.titleComputation of the electron beam quality [Formula: see text] factors for the NE2571, NE2571A and NE2581A thimble ionization chambers using PENELOPE.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number38
dspace.entity.typePublication

Files