Publication:
Good long-term adherence to continuous positive airway pressure therapy in patients with resistant hypertension and sleep apnea.

No Thumbnail Available

Date

2019-01-02

Authors

Campos-Rodriguez, Francisco
Navarro-Soriano, Cristina
Reyes-Nuñez, Nuria
Torres, Gerard
Caballero-Eraso, Candela
Lloberes, Patricia
Diaz-Cambriles, Trinidad
Somoza, Maria
Masa, Juan F
Gonzalez, Monica

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Although adequate adherence is paramount in achieving the beneficial effects of continuous positive airway pressure therapy in patients with obstructive sleep apnea, long-term adherence and the variables involved in continuous positive airway pressure compliance in patients with resistant hypertension and obstructive sleep apnea are yet unknown. We conducted a prospective, multicentre, observational study in 177 patients recruited from hypertensive units with resistant hypertension confirmed by means of 24-hr blood pressure monitoring (blood pressure ≥ 130 and/or ≥ 80 mmHg, despite taking at least three antihypertensive drugs or  3 drugs) and obstructive sleep apnea (apnea-hypopnea index ≥ 5 in a respiratory polygraph) who were prescribed continuous positive airway pressure treatment. Good adherence was defined as an average cumulative continuous positive airway pressure use of ≥ 4 hr per night at the end of the follow-up. A multivariate Cox regression analysis was performed to identify independent predictors of continuous positive airway pressure adherence. Patients were followed for a median of 57.6 (42-72) months after initiating continuous positive airway pressure therapy. At the end of the follow-up, the median continuous positive airway pressure use was 5.7 (inter-quartile range 3.9-6.6) hr per night, and 132 patients (74.5%) showed good continuous positive airway pressure adherence. The only baseline variable associated with poor adherence was the presence of previous stroke (hazard ratio 4.00, 95% confidence interval 1.92-8.31). Adequate adherence at 1 month also predicted good adherence at the end of the follow-up (hazard ratio 14.4, 95% confidence interval 4.94-56). Both variables also predicted adherence at a threshold of 6 hr per night. Our results show that good continuous positive airway pressure adherence is an achievable and feasible goal in patients with resistant hypertension and obstructive sleep apnea. Previous stroke and short-term adherence predicted long-term adherence.

Description

MeSH Terms

Aged
Continuous Positive Airway Pressure
Female
Humans
Hypertension
Male
Middle Aged
Prospective Studies
Sleep Apnea, Obstructive

DeCS Terms

CIE Terms

Keywords

adherence, continuous positive airway pressure, obstructive sleep apnea, resistant hypertension

Citation