Publication:
Intra- and Interobserver Reliability of Superb Microvascular Imaging (SMI) Doppler for Assessing Placental Microvasculature

dc.contributor.authorGarcia-Jimenez, Rocio
dc.contributor.authorAntonio Garcia-Mejido, Jose
dc.contributor.authorValero, Irene
dc.contributor.authorFernandez-Palacin, Ana
dc.contributor.authorBorrero, Carlota
dc.contributor.authorAntonio Sainz-Bueno, Jose
dc.contributor.authoraffiliation[Garcia-Jimenez, Rocio] Valme Univ Hosp, Dept Obstet & Gynecol, Seville 41014, Spain
dc.contributor.authoraffiliation[Antonio Garcia-Mejido, Jose] Valme Univ Hosp, Dept Obstet & Gynecol, Seville 41014, Spain
dc.contributor.authoraffiliation[Valero, Irene] Valme Univ Hosp, Dept Obstet & Gynecol, Seville 41014, Spain
dc.contributor.authoraffiliation[Borrero, Carlota] Valme Univ Hosp, Dept Obstet & Gynecol, Seville 41014, Spain
dc.contributor.authoraffiliation[Antonio Sainz-Bueno, Jose] Valme Univ Hosp, Dept Obstet & Gynecol, Seville 41014, Spain
dc.contributor.authoraffiliation[Antonio Garcia-Mejido, Jose] Univ Seville, Fac Med, Dept Obstet & Gynecol, Seville 41009, Spain
dc.contributor.authoraffiliation[Borrero, Carlota] Univ Seville, Fac Med, Dept Obstet & Gynecol, Seville 41009, Spain
dc.contributor.authoraffiliation[Antonio Sainz-Bueno, Jose] Univ Seville, Fac Med, Dept Obstet & Gynecol, Seville 41009, Spain
dc.contributor.authoraffiliation[Fernandez-Palacin, Ana] Univ Seville, Dept Prevent Med & Publ Hlth, Biostat Unit, Seville 41014, Spain
dc.date.accessioned2023-05-03T14:34:12Z
dc.date.available2023-05-03T14:34:12Z
dc.date.issued2022-08-01
dc.description.abstractObjective: Superb Microvascular Imaging (SMI) Doppler is a novel technique. We aim to evaluate intra- and interobserver reliability of SMI Doppler for the assessment of normal placental microvasculature. Materials and Methods: A prospective observational study was conducted including 11 pregnant patients. Ultrasonography placental assessment was performed on 28-weeks pregnant patients, by two expert examiners using SMI Doppler in one single visit. To evaluate interobserver reliability, the first examiner took measurements using SMI Doppler, followed then by the second examiner. Afterwards, the first examiner performed a second evaluation, in order to assess intraobserver reliability. Intraclass correlation coefficients (ICC) and Cohen's Kappa coefficient, and their 95% confidence intervals, were estimated for quantitative and qualitative parameters, respectively. Results: Intraobserver reliability was found to be excellent for all quantitative parameters, with all ICC values above 0.97. For qualitative variables, excellent reliability was obtained for the number of secondary villi, while the number of tertiary villi had an adequate reliability with a Cohen's Kappa coefficient of 0.792 (95% CI 0.38-1.17; p = 0.007). Interobserver ICCs ranged from 0.92 to 1.00 for all quantitative parameters, thus finding excellent interobserver reliability for all of them. An excellent reliability was also obtained for the number of secondary villi, while the reliability for the number of tertiary villi was found to be adequate. Conclusions: Our findings show that placental microvasculature measurements obtained by a single or two different examiners are reliable and reproducible. The good intra- and interobserver reliability results of SMI Doppler showed in our study stress the value of this technique in the evaluation of placental microvasculature, and thus research in this field is the step forward for the assessment of placental insufficiency.
dc.identifier.doi10.31083/j.ceog4908177
dc.identifier.essn2709-0094
dc.identifier.issn0390-6663
dc.identifier.unpaywallURLhttps://www.imrpress.com/journal/CEOG/49/8/10.31083/j.ceog4908177/pdf
dc.identifier.urihttp://hdl.handle.net/10668/21807
dc.identifier.wosID860532200020
dc.issue.number8
dc.journal.titleClinical and experimental obstetrics & gynecology
dc.journal.titleabbreviationClin. exp. obstet. gynecol.
dc.language.isoen
dc.organizationÁrea de Gestión Sanitaria Sur de Sevilla
dc.organizationÁrea de Gestión Sanitaria Sur de Sevilla
dc.organizationAGS - Sur de Sevilla
dc.organizationAGS - Sur de Sevilla
dc.publisherImr press
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectsuperb microvascular imaging
dc.subjectSMI Doppler
dc.subjectplacental microvasculature
dc.subjectreproducibility
dc.subjectreliability
dc.subjectVascularization
dc.subjectGrowth
dc.subjectAngiography
dc.titleIntra- and Interobserver Reliability of Superb Microvascular Imaging (SMI) Doppler for Assessing Placental Microvasculature
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number49
dc.wostypeArticle
dspace.entity.typePublication

Files