Publication:
Coherent silicon photonic interferometric biosensor with an inexpensive laser source for sensitive label-free immunoassays

dc.contributor.authorLeuermann, Jonas
dc.contributor.authorStamenkovic, Vladimir
dc.contributor.authorRamirez-Priego, Patricia
dc.contributor.authorSánchez-Postigo, Alejandro
dc.contributor.authorFernández-Gavela, Adrián
dc.contributor.authorChapman, Cole A.
dc.contributor.authorBailey, Ryan C.
dc.contributor.authorLechuga, Laura M.
dc.contributor.authorPerez-Inestrosa, Ezequiel
dc.contributor.authorCollado, Daniel
dc.contributor.authorHalir, Robert
dc.contributor.authorMolina-Fernández, Íñigo
dc.contributor.authoraffiliation[Leuermann,J; Stamenkovic,V; Perez-Inestrosa,E; Collado,D; Halir,R; Molina-Fernández,Í] Bionand Center for Nanomedicine and Biotechnology, Málaga, Spain. [Leuermann,J; Sánchez-Postigo,A; Halir,R; Molina-Fernández,Í] Departamento de Ingeniería de Comunicaciones, University of Málaga, ETSI Telecomunicación, Málaga, Spain. [Stamenkovic,V; Perez-Inestrosa,E; Collado,D] Departamento de Química Orgánica, Facultad de Ciencias, University of Málaga, Málaga, Spain. [Ramirez-Priego,P, Lechuga,LM] Nanobiosensors and Bioanalytical Applications Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, BIST and CIBER-BBN Campus UAB, Barcelona, Spain. [Fernández-Gavela,A] Departamento de Física, Universidad de Oviedo, Oviedo, Spain. [Chapman,CA; Bailey,RC] Department of Chemistry, University of Michigan, Ann Arbor, Michigan, USA.
dc.contributor.funderHorizon 2020 Framework Programme (EuroNanoMed 3-H2020 DrNanoDAII); Ministerio de Economía y Competitividad (2019/PCI 2019-2, CTQ2017-86994-R, SEV-2017-0706); Junta de Andalucía, Proyectos Excelencia-Retos (P18-RT-1453, P18-RT-793); Fondos Europeos de Desarrollo Regional (CTQ2016-75870-P, PID2019-104293GB-I00, RD16/0006/0012, TEC2016-80718-R, UMA18-FEDERJA-007, UMA18-FEDERJA-219); H2020 Marie Skłodowska-Curie Actions (713721).
dc.date.accessioned2021-06-17T13:08:22Z
dc.date.available2021-06-17T13:08:22Z
dc.date.issued2020-12-08
dc.description.abstractOver the past two decades, integrated photonic sensors have been of major interest to the optical biosensor community due to their capability to detect low concentrations of molecules with label-free operation. Among these, interferometric sensors can be read-out with simple, fixed-wavelength laser sources and offer excellent detection limits but can suffer from sensitivity fading when not tuned to their quadrature point. Recently, coherently detected sensors were demonstrated as an attractive alternative to overcome this limitation. Here we show, for the first time, to the best of our knowledge, that this coherent scheme provides sub-nanogram per milliliter limits of detection in C-reactive protein immunoassays and that quasi-balanced optical arm lengths enable operation with inexpensive Fabry-Perot-type lasers sources at telecom wavelengths.es_ES
dc.description.versionYeses_ES
dc.identifier.citationLeuermann J, Stamenkovic V, Ramirez-Priego P, Sánchez-Postigo A, Fernández-Gavela A, Chapman CA, et al. Coherent silicon photonic interferometric biosensor with an inexpensive laser source for sensitive label-free immunoassays. Opt Lett. 2020 Dec 8;45(24):6595-6598.es_ES
dc.identifier.doi10.1364/OL.411635es_ES
dc.identifier.essn1539-4794
dc.identifier.issn0146-9592
dc.identifier.pmid33325848es_ES
dc.identifier.urihttp://hdl.handle.net/10668/3374
dc.journal.titleOptics Letters
dc.language.isospa
dc.page.number4 p.
dc.publisherOptical Society of Americaes_ES
dc.relation.publisherversionhttps://www.osapublishing.org/ol/fulltext.cfm?uri=ol-45-24-6595&id=444310es_ES
dc.rights.accessRightsAcceso abiertoes_ES
dc.subjectPhotonses_ES
dc.subjectFotoneses_ES
dc.subjectBiosensing techniqueses_ES
dc.subjectTécnicas biosensibleses_ES
dc.subjectLaserses_ES
dc.subjectRayos laseres_ES
dc.subjectInterferometryes_ES
dc.subjectInterferometríaes_ES
dc.subjectC-Reactive Proteines_ES
dc.subjectProteína C-Reactivaes_ES
dc.subjectLimit of detectiones_ES
dc.subjectLímite de detecciónes_ES
dc.subjectImmunoassayes_ES
dc.subjectInmunoensayoes_ES
dc.subject.meshMedical Subject Headings::Phenomena and Processes::Physical Phenomena::Optical Phenomena::Light::Photonses_ES
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Molecular Probe Techniques::Biosensing Techniqueses_ES
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Optical Devices::Laserses_ES
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Interferometryes_ES
dc.subject.meshMedical Subject Headings::Chemicals and Drugs::Amino Acids, Peptides, and Proteins::Proteins::Albumins::C-Reactive Proteines_ES
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Immunologic Techniques::Immunoassayes_ES
dc.titleCoherent silicon photonic interferometric biosensor with an inexpensive laser source for sensitive label-free immunoassayses_ES
dc.typeletter
dc.type.hasVersionVoR
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Leuermann_CoherentSilicon.pdf
Size:
1.72 MB
Format:
Adobe Portable Document Format
Description:
Carta