Publication: Determinants and Differences in Satisfaction with the Inhaler Among Patients with Asthma or COPD.
dc.contributor.author | Plaza, Vicente | |
dc.contributor.author | Giner, Jordi | |
dc.contributor.author | Curto, Elena | |
dc.contributor.author | Alonso-Ortiz, M Belen | |
dc.contributor.author | Orue, Miren Itxaso | |
dc.contributor.author | Vega, Jose Maria | |
dc.contributor.author | Cosio, Borja G | |
dc.contributor.group | group of investigators of the RE-TAI study | |
dc.date.accessioned | 2023-01-25T13:43:07Z | |
dc.date.available | 2023-01-25T13:43:07Z | |
dc.date.issued | 2019-10-03 | |
dc.description.abstract | Satisfaction with the inhaler is an important determinant of treatment adherence in patients with asthma and chronic obstructive pulmonary disease (COPD). However, few studies have compared these 2 groups to identify the factors associated with satisfaction with the inhaler. To assess and compare satisfaction with the inhaler in patients with asthma or COPD and to determine the variables associated with high inhaler satisfaction. A multicenter, cross-sectional study of 816 patients (406 with asthma and 410 with COPD) was conducted. Satisfaction was assessed with the Feeling of Satisfaction with Inhaler (FSI-10) questionnaire. All participants completed the Test of Adherence to Inhalers and either the Asthma Control Test (ACT) or the COPD Assessment Test (CAT). Overall, the asthma group was significantly more satisfied with the inhaler (mean [standard deviation] FSI-10 scores: 44.1 [6.5] vs 42.0 [7.7]; P Age, disease control, and training in inhalation technique all play a more significant role than the specific diagnosis in explaining satisfaction with the device in patients with asthma and COPD. These findings underscore the need to provide better training and more active monitoring of the inhalation technique to improve patient satisfaction, treatment adherence, and clinical outcomes. | |
dc.description.version | Si | |
dc.identifier.citation | Plaza V, Giner J, Curto E, Alonso-Ortiz MB, Orue MI, Vega JM, et al. Determinants and Differences in Satisfaction with the Inhaler Among Patients with Asthma or COPD. J Allergy Clin Immunol Pract. 2020 Feb;8(2):645-653 | |
dc.identifier.doi | 10.1016/j.jaip.2019.09.020 | |
dc.identifier.essn | 2213-2201 | |
dc.identifier.pmid | 31586668 | |
dc.identifier.unpaywallURL | https://doi.org/10.1016/j.jaip.2019.09.020 | |
dc.identifier.uri | http://hdl.handle.net/10668/14587 | |
dc.issue.number | 2 | |
dc.journal.title | The journal of allergy and clinical immunology. In practice | |
dc.journal.titleabbreviation | J Allergy Clin Immunol Pract | |
dc.language.iso | en | |
dc.organization | Hospital Universitario Virgen de la Victoria | |
dc.organization | Hospital Universitario Regional de Málaga | |
dc.organization | Hospital Universitario Virgen del Rocío | |
dc.organization | Hospital Universitario Virgen Macarena | |
dc.page.number | 645-653 | |
dc.provenance | Realizada la curación de contenido 24/03/2025 | |
dc.publisher | Elsevier | |
dc.pubmedtype | Journal Article | |
dc.pubmedtype | Multicenter Study | |
dc.pubmedtype | Research Support, Non-U.S. Gov't | |
dc.relation.publisherversion | https://linkinghub.elsevier.com/retrieve/pii/S2213-2198(19)30846-3 | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Asthma | |
dc.subject | Chronic obstructive | |
dc.subject | Nebulizers | |
dc.subject | Patient compliance | |
dc.subject | Patient satisfaction | |
dc.subject | Pulmonary disease | |
dc.subject | Self-reported success | |
dc.subject | Vaporizers | |
dc.subject.decs | Nebulizadores y Vaporizadores | |
dc.subject.decs | Enfermedad Pulmonar Obstructiva Crónica | |
dc.subject.decs | Inhalación | |
dc.subject.decs | Monitoreo del Ambiente | |
dc.subject.decs | Satisfacción del Paciente | |
dc.subject.mesh | Administration, Inhalation | |
dc.subject.mesh | Asthma | |
dc.subject.mesh | Bronchodilator Agents | |
dc.subject.mesh | Cross-Sectional Studies | |
dc.subject.mesh | Humans | |
dc.subject.mesh | Nebulizers and Vaporizers | |
dc.subject.mesh | Patient Satisfaction | |
dc.subject.mesh | Personal Satisfaction | |
dc.subject.mesh | Pulmonary Disease, Chronic Obstructive | |
dc.title | Determinants and Differences in Satisfaction with the Inhaler Among Patients with Asthma or COPD. | |
dc.type | research article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 8 | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Plaza_DeterminantsAnd.pdf
- Size:
- 397 KB
- Format:
- Adobe Portable Document Format