Publication:
Complications of the Percutaneous Mitral Valve Edge-To-Edge Repair: Role of Transesophageal Echocardiography.

dc.contributor.authorFlores, Guisela
dc.contributor.authorMesa, Dolores
dc.contributor.authorOjeda, Soledad
dc.contributor.authorde Lezo, Javier Suarez
dc.contributor.authorGonzalez-Manzanares, Rafael
dc.contributor.authorDueñas, Guillermo
dc.contributor.authorPan, Manuel
dc.date.accessioned2023-05-03T14:09:23Z
dc.date.available2023-05-03T14:09:23Z
dc.date.issued2022-08-11
dc.description.abstractThe use of transcatheter edge-to-edge repair for the treatment of mitral regurgitation has markedly increased in the last few years. The rate of adverse events related to the procedure is low; however, some of the complications that may occur are potentially dangerous. Due to the growing popularity of the technique, which is no longer limited to high-volume centers, knowledge of the complications related to the procedure is fundamental. Transesophageal echocardiography has a key role in the guidance of the intervention while allowing for the avoidance of most of these adverse events, as well as enabling us to diagnose them early. In this article, we review the main complications that might present during a transcatheter mitral edge-to-edge repair procedure (tamponade, thromboembolic events, single leaflet device attachment, device embolization, vascular injury…) while highlighting key aspects of transesophageal echocardiographic monitoring in the prevention and prompt diagnosis of these complications.
dc.description.versionSi
dc.identifier.citationFlores G, Mesa D, Ojeda S, de Lezo JS, Gonzalez-Manzanares R, Dueñas G, et al. Complications of the Percutaneous Mitral Valve Edge-To-Edge Repair: Role of Transesophageal Echocardiography. J Clin Med. 2022 Aug 14;11(16):474
dc.identifier.doi10.3390/jcm11164747
dc.identifier.issn2077-0383
dc.identifier.pmcPMC9410310
dc.identifier.pmid36012985
dc.identifier.pubmedURLhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC9410310/pdf
dc.identifier.unpaywallURLhttps://www.mdpi.com/2077-0383/11/16/4747/pdf?version=1660613112
dc.identifier.urihttp://hdl.handle.net/10668/21334
dc.issue.number16
dc.journal.titleJournal of clinical medicine
dc.journal.titleabbreviationJ Clin Med
dc.language.isoen
dc.organizationHospital Universitario Reina Sofía
dc.organizationInstituto Maimónides de Investigación Biomédica de Córdoba-IMIBIC
dc.page.number11
dc.publisherMDPI
dc.pubmedtypeJournal Article
dc.pubmedtypeReview
dc.relation.publisherversionhttps://www.mdpi.com/2077-0383/11/16/4747
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectComplications
dc.subjectEdge-to-edge repair
dc.subjectMitral regurgitation
dc.subject.decsEcocardiografía transesofágica
dc.subject.decsEmbolización terapéutica
dc.subject.decsInsuficiencia de la válvula mitral
dc.subject.decsLesiones del sistema vascular
dc.subject.decsProcedimientos quirúrgicos vasculares
dc.subject.decsTromboembolia
dc.subject.meshMitral valve insufficiency
dc.subject.meshEchocardiography, transesophageal
dc.subject.meshVascular system injuries
dc.subject.meshEmbolization, therapeutic
dc.subject.meshVascular surgical procedures
dc.subject.meshThromboembolism
dc.titleComplications of the Percutaneous Mitral Valve Edge-To-Edge Repair: Role of Transesophageal Echocardiography.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number11
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PMC9410310.pdf
Size:
1.72 MB
Format:
Adobe Portable Document Format