Publication: Analytical performance of the Alere™ i Influenza A&B assay for the rapid detection of influenza viruses.
dc.contributor.author | Riazzo, Cristina | |
dc.contributor.author | Pérez-Ruiz, Mercedes | |
dc.contributor.author | Sanbonmatsu-Gámez, Sara | |
dc.contributor.author | Pedrosa-Corral, Irene | |
dc.contributor.author | Gutiérrez-Fernández, José | |
dc.contributor.author | Navarro-Marí, José-María | |
dc.date.accessioned | 2023-01-25T08:30:20Z | |
dc.date.available | 2023-01-25T08:30:20Z | |
dc.date.issued | 2015-11-25 | |
dc.description.abstract | The analytical performance of the new Alere™ i Influenza A&B kit (AL-Flu) assay, based on isothermal nucleic acids amplification, was evaluated and compared with an antigen detection method, SD Bioline Influenza Virus Antigen Test (SDB), and an automated real-time RT-PCR, Simplexa™ Flu A/B & VRS Direct assay (SPX), for detection of influenza viruses. An "in-house" RT-PCR was used as the reference method. Sensitivity of AL-Flu, SDB, and SPX was 71.7%, 34.8%, and 100%, respectively. Specificity was 100% for all techniques. The turnaround time was 13min for AL-Flu, 15min for SDB, and 75min for SPX. The Alere™ i Influenza A&B assay is an optimal point-of-care assay for influenza diagnosis in clinical emergency settings, and is more sensitive and specific than antigen detection methods. | |
dc.identifier.doi | 10.1016/j.eimc.2015.10.006 | |
dc.identifier.essn | 1578-1852 | |
dc.identifier.pmc | PMC7103361 | |
dc.identifier.pmid | 26620605 | |
dc.identifier.pubmedURL | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7103361/pdf | |
dc.identifier.unpaywallURL | https://doi.org/10.1016/j.eimc.2015.10.006 | |
dc.identifier.uri | http://hdl.handle.net/10668/9647 | |
dc.issue.number | 7 | |
dc.journal.title | Enfermedades infecciosas y microbiologia clinica | |
dc.journal.titleabbreviation | Enferm Infecc Microbiol Clin | |
dc.language.iso | en | |
dc.language.iso | es | |
dc.organization | Hospital Universitario Virgen de las Nieves | |
dc.page.number | 438-440 | |
dc.pubmedtype | Comparative Study | |
dc.pubmedtype | Journal Article | |
dc.rights.accessRights | open access | |
dc.subject | Detección rápida | |
dc.subject | Gripe | |
dc.subject | Influenza | |
dc.subject | Molecular testing | |
dc.subject | Método molecular | |
dc.subject | Rapid detection | |
dc.subject.mesh | Humans | |
dc.subject.mesh | Influenza A virus | |
dc.subject.mesh | Influenza B virus | |
dc.subject.mesh | Influenza, Human | |
dc.subject.mesh | Molecular Diagnostic Techniques | |
dc.subject.mesh | Nucleic Acid Amplification Techniques | |
dc.subject.mesh | Retrospective Studies | |
dc.subject.mesh | Time Factors | |
dc.title | Analytical performance of the Alere™ i Influenza A&B assay for the rapid detection of influenza viruses. | |
dc.type | research article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 35 | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1