Publication:
Fracturas femorales periprotésicas de rodilla tratadas con clavo intramedular retrógrado y osteosíntesis con placa: comparación de resultados a medio-largo plazo

Loading...
Thumbnail Image

Date

2012-01

Authors

Navarro Carmona, Francisco Javier
Serrano Montilla, José
Montañez Heredia, Elvira

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Sociedad Andaluza de Traumatología y Ortopedia
Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

INTRODUCCIÓN: La fractura periprotésica femoral de rodilla constituye una de las complicaciones mas temidas por sus repercusiones. Su incidencia aumenta debido tanto al mayor número de artroplastias totales de rodilla (ATR) implantadas como al aumento de la esperanza de vida de la población. El objetivo del estudio es analizar algunos aspectos perioperatorios del tratamiento de estas fracturas comparando el uso de osteosíntesis con placas y el enclavado retrógrado en los pacientes con fracturas femorales periprotésicas de rodilla con implante estable. MATERIAL Y MÉTODOS: Se estudian retrospectivamente 18 casos tratados consecutivamente en nuestro hospital (3 hombres y 15 mujeres; edad media, 72.7 años) entre los años 2000 y 2009. Todas las fracturas asentaban en fémur distal y sobre implante estable. Fueron tratados mediante enclavado retrógrado 8 (Grupo I) y 10 con placas (Grupo II). Se analizan mediante el test de la U de Mann-Withney y el test exacto de Fisher, con valores significativos de p£0.05, las variables: estancia media hospitalaria, necesidad de transfusión indicada con cifras de hemoglobina menor a 8mg/ml, alineación radiológica preoperatoria y postoperatoria de la ATR, medida según el eje anatómico tibiofemoral, tiempo de consolidación e incidencia de complicaciones locales en ambos grupos. RESULTADOS: No hemos encontrado diferencias estadísticamente significativas entre ambos grupos para ninguna de las variables analizadas. Las complicaciones locales son más frecuentes en el Grupo I (75% pacientes) que en el Grupo II (50% pacientes). La necesidad de transfusión es mayor en el Grupo II (40%) que en el Grupo I (12.5%). CONClUSIONES: El tipo de implante utilizado en el tratamiento de las fracturas femorales periprotésicas no influye de forma significativa en los aspectos Perioperatorios. El tratamiento para este tipo de fracturas debe ser elegido de forma individualizada en función de tipo de fractura, características del paciente y estabilidad y modelo de prótesis de rodilla primaria.
INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Description

MeSH Terms

Medical Subject Headings::Diseases::Wounds and Injuries::Fractures, Bone::Periprosthetic Fractures
Medical Subject Headings::Diseases::Wounds and Injuries::Fractures, Bone::Femoral Fractures
Medical Subject Headings::Diseases::Pathological Conditions, Signs and Symptoms::Pathologic Processes::Postoperative Complications
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Orthopedic Procedures::Fracture Fixation::Fracture Fixation, Internal::Fracture Fixation, Intramedullary
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Prosthesis Implantation::Arthroplasty, Replacement::Arthroplasty, Replacement, Knee
Medical Subject Headings::Named Groups::Persons::Age Groups::Adult::Aged
Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Bone Nails
Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Bone Plates
Medical Subject Headings::Anatomy::Musculoskeletal System::Skeleton::Joints::Knee Joint

DeCS Terms

CIE Terms

Keywords

Fibrosarcoma, Braquiorradialis, PRGF, Acromioplastia, Manguito, Síndrome Subacromial, UCLA, Complicaciones Postoperatorias, Fijación Intramedular de Fracturas, Artroplastia de Reemplazo de Rodilla, Anciano, Articulación de la Rodilla, Fracturas del Fémur, Fracturas Periprotésicas

Citation

Navarro Carmona, Francisco Javier; Serrano Montilla, José; Montañez Heredia, Elvira. Fracturas femorales periprotésicas de rodilla tratadas con clavo intramedular retrógrado y osteosíntesis con placa: comparación de resultados a medio-largo plazo. Revista de la Sociedad Andaluza de Traumatología y Ortopedia. 2012;29(1/2):31-40