Publication:
His-Bundle Pacing From the Right Atrium in a Patient With Tetralogy of Fallot and a Prosthetic Tricuspid Valve.

dc.contributor.authorTorres-Quintero, Lucia
dc.contributor.authorMolina-Lerma, Manuel
dc.contributor.authorCabrera-Borrego, Eva
dc.contributor.authorGarcia-Orta, Rocio
dc.contributor.authorTercedor-Sanchez, Luis
dc.contributor.authorAlvarez, Miguel
dc.date.accessioned2023-02-09T09:35:44Z
dc.date.available2023-02-09T09:35:44Z
dc.date.issued2020
dc.description.abstractA mechanical tricuspid valve makes it difficult to implant a transvenous endocardial lead in the right ventricle , necessitating pacing by alternative nonphysiological methods such as implanting an epicardial lead and pacing through the coronary sinus . Permanent His-bundle pacing is an increasingly common method because it is the most physiological form of pacing and it can provide an effective alternative because the right atrial portion of the His bundle remains unaltered by the prosthetic tricuspid valve . Despite that, there are a small number of reported cases in patients with prosthetic tricuspid valve (1,2), and none of them were described in a patient with congenital heart disease .
dc.description.versionSi
dc.identifier.citationTorres-Quintero L, Molina-Lerma M, Cabrera-Borrego E, García-Orta R, Tercedor-Sánchez L, Álvarez M. His-Bundle Pacing From the Right Atrium in a Patient With Tetralogy of Fallot and a Prosthetic Tricuspid Valve. JACC Clin Electrophysiol. 2020 Jun;6(6):745-746.
dc.identifier.doi10.1016/j.jacep.2020.03.011
dc.identifier.essn2405-5018
dc.identifier.pmid32553229
dc.identifier.unpaywallURLhttps://doi.org/10.1016/j.jacep.2020.03.011
dc.identifier.urihttp://hdl.handle.net/10668/15758
dc.issue.number6
dc.journal.titleJACC. Clinical electrophysiology
dc.journal.titleabbreviationJACC Clin Electrophysiol
dc.language.isoen
dc.organizationIBS
dc.page.number745-746
dc.provenanceRealizada la curación de contenido 28/05/2025.
dc.publisherElsevier Inc.
dc.pubmedtypeJournal Article
dc.relation.publisherversionhttps://linkinghub.elsevier.com/retrieve/pii/S2405-500X(20)30247-4
dc.rights.accessRightsRestricted Access
dc.subjectFallot tetralogy
dc.subjectHis-bundle pacing
dc.subjecttricuspid prosthetic
dc.subject.decsVálvula tricúspide
dc.subject.decsPacientes
dc.subject.decsPlomo
dc.subject.decsCardiopatías congénitas
dc.subject.decsFascículo atrioventricular
dc.subject.decsVentrículos cardíacos
dc.subject.decsSeno coronario
dc.subject.meshCardiac Catheterization
dc.subject.meshHeart Atria
dc.subject.meshHumans
dc.subject.meshTetralogy of Fallot
dc.subject.meshTricuspid Valve
dc.subject.meshTricuspid Valve Insufficiency
dc.titleHis-Bundle Pacing From the Right Atrium in a Patient With Tetralogy of Fallot and a Prosthetic Tricuspid Valve.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number6
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
RISalud_Accesorestringido.pdf
Size:
93.39 KB
Format:
Adobe Portable Document Format