Publication:
Edge vascular response after polymer-free vs. polymer-based paclitaxel-eluting stent implantation.

dc.contributor.authorOtsuki, Shuji
dc.contributor.authorShiratori, Yoshitaka
dc.contributor.authorBrugaletta, Salvatore
dc.contributor.authorCola, Clarissa
dc.contributor.authorGarcía Del Blanco, Bruno
dc.contributor.authorRuiz-Salmeron, Rafael
dc.contributor.authorDíaz, José Francisco
dc.contributor.authorPinar, Eduardo
dc.contributor.authorMartí, Vicens
dc.contributor.authorGarcía-Picart, Juan
dc.contributor.authorMartín-Yuste, Victoria
dc.contributor.authorSabaté, Manel
dc.contributor.authoraffiliation[Otsuki,S; Shiratori,Y; Brugaletta,S; Martín-Yuste,V; Sabaté,M] Thorax Institute, Department of Cardiology, Hospital Clinic, IDIBAPS, University of Barcelona, Barcelona. [Cola,C; Martí,V; García-Picart,J] Department of Cardiology, Sant Pau Hospital, Barcelona. [García Del Blanco,B] Department of Cardiology, Vall d’Hebron Hospital, Barcelona. [Ruiz-Salmerón,R] Department of Cardiology, Virgen de Macarena Hospìtal, Seville. [Díaz,JF] Department of Cardiology, Juan Ramon Jimenez Hospital, Huelva. [Pinar,E] Department of Cardiology, Virgen de la Arrixaca Hospital, Murcia, Spain.es
dc.date.accessioned2015-10-21T12:19:04Z
dc.date.available2015-10-21T12:19:04Z
dc.date.issued2014-09-22
dc.descriptionComparative Study; Journal Article; Multicenter Study; Randomized Controlled Trial;es
dc.description.abstractBACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.es
dc.description.versionYeses
dc.identifier.citationOtsuki S, Shiratori Y, Brugaletta S, Cola C, García Del Blanco B, Ruiz-Salmeron R, et al. Edge vascular response after polymer-free vs. polymer-based paclitaxel-eluting stent implantation. Circ. J. 2014; 78(11):2657-64es
dc.identifier.doi10.1253/circj.CJ-14-0345
dc.identifier.essn1347-4820
dc.identifier.issn1346-9843
dc.identifier.pmid25241887
dc.identifier.urihttp://hdl.handle.net/10668/2030
dc.journal.titleCirculation journal : official journal of the Japanese Circulation Society
dc.language.isoen
dc.publisherJapanese Circulation Societyes
dc.relation.publisherversionhttps://www.jstage.jst.go.jp/article/circj/78/11/78_CJ-14-0345/_articlees
dc.rights.accessRightsopen access
dc.subjectDrug-eluting stentes
dc.subjectIntravascular ultrasoundes
dc.subjectEdge vascular responsees
dc.subjectPolymer-based paclitaxel-eluting stentes
dc.subjectPolymer-free paclitaxel-eluting stentes
dc.subjectStents Liberadores de Fármacoses
dc.subjectEstudios de Seguimientoes
dc.subjectPaclitaxeles
dc.subjectEstudios Prospectivoses
dc.subjectUltrasonografía Intervencionales
dc.subject.meshMedical Subject Headings::Named Groups::Persons::Age Groups::Adult::Agedes
dc.subject.meshMedical Subject Headings::Chemicals and Drugs::Chemical Actions and Uses::Pharmacologic Actions::Therapeutic Uses::Antineoplastic Agents::Antineoplastic Agents, Phytogenices
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Stents::Drug-Eluting Stentses
dc.subject.meshMedical Subject Headings::Check Tags::Femalees
dc.subject.meshMedical Subject Headings::Health Care::Health Care Quality, Access, and Evaluation::Quality of Health Care::Health Care Evaluation Mechanisms::Epidemiologic Study Characteristics as Topic::Epidemiologic Studies::Cohort Studies::Follow-Up Studieses
dc.subject.meshMedical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humanses
dc.subject.meshMedical Subject Headings::Check Tags::Malees
dc.subject.meshMedical Subject Headings::Named Groups::Persons::Age Groups::Adult::Middle Agedes
dc.subject.meshMedical Subject Headings::Chemicals and Drugs::Organic Chemicals::Hydrocarbons::Hydrocarbons, Cyclic::Hydrocarbons, Alicyclic::Cycloparaffins::Cyclodecanes::Taxoids::Paclitaxeles
dc.subject.meshMedical Subject Headings::Chemicals and Drugs::Macromolecular Substances::Polymerses
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Epidemiologic Methods::Epidemiologic Study Characteristics as Topic::Epidemiologic Studies::Cohort Studies::Longitudinal Studies::Prospective Studieses
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Ultrasonography::Ultrasonography, Interventionales
dc.titleEdge vascular response after polymer-free vs. polymer-based paclitaxel-eluting stent implantation.es
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Otsuki_EdgeVascularResponse.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format
Description:
Artículo publicado