Publication: Application of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis.
dc.contributor.author | Remes-Troche, José María | |
dc.contributor.author | Jiménez-García, Victoria Alejandra | |
dc.contributor.author | García-Montes, Josefa María | |
dc.contributor.author | Hergueta-Delgado, Pedro | |
dc.contributor.author | Roesch-Dietlen, Federico | |
dc.contributor.author | Herrerías-Gutiérrez, Juan Manuel | |
dc.contributor.authoraffiliation | [Remes-Troche,JM; Roesch-Dietlen,F] Digestive Physiology and Motility Lab, Medical Biological Research Institute, Universidad Veracruzana, Veracruz, México.[Jiménez-García,VA; Hergueta-Delgado,P; Herrerías-Gutiérrez,JM] Gastroenterology Service, Virgen Macarena University Hospital, Seville, Spain. | es |
dc.date.accessioned | 2016-03-08T10:49:37Z | |
dc.date.available | 2016-03-08T10:49:37Z | |
dc.date.issued | 2013-09-17 | |
dc.description | Journal Article; | es |
dc.description.abstract | BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis. | es |
dc.description.version | Yes | es |
dc.identifier.citation | Remes-Troche JM, Jiménez-García VA, García-Montes JM, Hergueta-Delgado P, Roesch-Dietlen F, Herrerías-Gutiérrez JM. Application of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis. Clin Exp Gastroenterol. 2013; 6:185-92 | es |
dc.identifier.doi | 10.2147/CEG.S45215 | |
dc.identifier.essn | 1178-7023 | |
dc.identifier.pmc | PMC3782512 | |
dc.identifier.pmid | 24068872 | |
dc.identifier.uri | http://hdl.handle.net/10668/2157 | |
dc.journal.title | Clinical and experimental gastroenterology | |
dc.language.iso | en | |
dc.publisher | Dove Medical Press | es |
dc.relation.publisherversion | http://www.dovepress.com/application-of-colon-capsule-endoscopy-cce-to-evaluate-the-whole-gastr-peer-reviewed-article-CEG | es |
dc.rights.accessRights | open access | |
dc.subject | Capsule endoscopy | es |
dc.subject | Colon | es |
dc.subject | Gastrointestinal tract | es |
dc.subject | Small bowel | es |
dc.subject | Endoscopios en cápsulas | es |
dc.subject | Endoscopía capsular | es |
dc.subject | Colonoscopía | es |
dc.subject | Tracto gastrointestinal | es |
dc.subject | Intestino delgado | es |
dc.subject.mesh | Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Diagnostic Equipment::Endoscopes::Endoscopes, Gastrointestinal::Capsule Endoscopes | es |
dc.subject.mesh | Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Techniques, Surgical::Endoscopy::Endoscopy, Digestive System::Endoscopy, Gastrointestinal::Capsule Endoscopy | es |
dc.subject.mesh | Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Techniques, Digestive System::Endoscopy, Digestive System::Endoscopy, Gastrointestinal::Colonoscopy | es |
dc.subject.mesh | Medical Subject Headings::Anatomy::Digestive System::Gastrointestinal Tract | es |
dc.subject.mesh | Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans | es |
dc.subject.mesh | Medical Subject Headings::Anatomy::Digestive System::Gastrointestinal Tract::Intestines::Intestine, Small | es |
dc.subject.mesh | Medical Subject Headings::Check Tags::Male | es |
dc.title | Application of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis. | es |
dc.type | research article | |
dc.type.hasVersion | VoR | |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- RemesTrocheJM_ApplicationColonCapsule .pdf
- Size:
- 912.28 KB
- Format:
- Adobe Portable Document Format
- Description:
- Artículo publicado