Publication:
Application of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis.

dc.contributor.authorRemes-Troche, José María
dc.contributor.authorJiménez-García, Victoria Alejandra
dc.contributor.authorGarcía-Montes, Josefa María
dc.contributor.authorHergueta-Delgado, Pedro
dc.contributor.authorRoesch-Dietlen, Federico
dc.contributor.authorHerrerías-Gutiérrez, Juan Manuel
dc.contributor.authoraffiliation[Remes-Troche,JM; Roesch-Dietlen,F] Digestive Physiology and Motility Lab, Medical Biological Research Institute, Universidad Veracruzana, Veracruz, México.[Jiménez-García,VA; Hergueta-Delgado,P; Herrerías-Gutiérrez,JM] Gastroenterology Service, Virgen Macarena University Hospital, Seville, Spain.es
dc.date.accessioned2016-03-08T10:49:37Z
dc.date.available2016-03-08T10:49:37Z
dc.date.issued2013-09-17
dc.descriptionJournal Article;es
dc.description.abstractBACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.es
dc.description.versionYeses
dc.identifier.citationRemes-Troche JM, Jiménez-García VA, García-Montes JM, Hergueta-Delgado P, Roesch-Dietlen F, Herrerías-Gutiérrez JM. Application of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis. Clin Exp Gastroenterol. 2013; 6:185-92es
dc.identifier.doi10.2147/CEG.S45215
dc.identifier.essn1178-7023
dc.identifier.pmcPMC3782512
dc.identifier.pmid24068872
dc.identifier.urihttp://hdl.handle.net/10668/2157
dc.journal.titleClinical and experimental gastroenterology
dc.language.isoen
dc.publisherDove Medical Presses
dc.relation.publisherversionhttp://www.dovepress.com/application-of-colon-capsule-endoscopy-cce-to-evaluate-the-whole-gastr-peer-reviewed-article-CEGes
dc.rights.accessRightsopen access
dc.subjectCapsule endoscopyes
dc.subjectColones
dc.subjectGastrointestinal tractes
dc.subjectSmall boweles
dc.subjectEndoscopios en cápsulases
dc.subjectEndoscopía capsulares
dc.subjectColonoscopíaes
dc.subjectTracto gastrointestinales
dc.subjectIntestino delgadoes
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Diagnostic Equipment::Endoscopes::Endoscopes, Gastrointestinal::Capsule Endoscopeses
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Techniques, Surgical::Endoscopy::Endoscopy, Digestive System::Endoscopy, Gastrointestinal::Capsule Endoscopyes
dc.subject.meshMedical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Techniques, Digestive System::Endoscopy, Digestive System::Endoscopy, Gastrointestinal::Colonoscopyes
dc.subject.meshMedical Subject Headings::Anatomy::Digestive System::Gastrointestinal Tractes
dc.subject.meshMedical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humanses
dc.subject.meshMedical Subject Headings::Anatomy::Digestive System::Gastrointestinal Tract::Intestines::Intestine, Smalles
dc.subject.meshMedical Subject Headings::Check Tags::Malees
dc.titleApplication of colon capsule endoscopy (CCE) to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis.es
dc.typeresearch article
dc.type.hasVersionVoR
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RemesTrocheJM_ApplicationColonCapsule .pdf
Size:
912.28 KB
Format:
Adobe Portable Document Format
Description:
Artículo publicado