Publication:
High Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis.

dc.contributor.authorGarrido-Castro, Juan L
dc.contributor.authorCurbelo, Rafael
dc.contributor.authorMazzucchelli, Ramon
dc.contributor.authorDominguez-Gonzalez, Maria E
dc.contributor.authorGonzalez-Navas, Cristina
dc.contributor.authorFlores Robles, Bryan J
dc.contributor.authorZarco, Pedro
dc.contributor.authorMulero, Juan
dc.contributor.authorCea-Calvo, Luis
dc.contributor.authorArteaga, María J
dc.contributor.authorFont-Ugalde, Pilar
dc.contributor.authorCarmona, Loreto
dc.contributor.authorCollantes-Estevez, Eduardo
dc.date.accessioned2023-01-25T10:11:43Z
dc.date.available2023-01-25T10:11:43Z
dc.date.issued2018-02-28
dc.description.abstractConventional measures of spinal mobility used in the assessment of patients with axial spondyloarthritis (axSpA), such as the Bath Ankylosing Spondylitis Metrology Index and its components, are subject to interobserver variability. The University of Córdoba Ankylosing Spondylitis Metrology Index (UCOASMI) is a validated composite index based on a motion video-capture system, UCOTrack. Our objective was to assess its reproducibility in clinical practice settings. We carried out an observational study of repeated measures in 3 centers. Video-capture systems were installed and adapted to clinical rooms. Patients with axSpA and stable disease were selected by consecutive stratified sampling [disease duration, sex, and the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI)]. Intraobserver reliability of the UCOASMI and of conventional measures was tested 3-5 days apart. For interobserver reliability, 3 patients from each center were evaluated in the other centers, within 3-7 days. The intraclass correlation coefficients (ICC) were calculated. Thirty patients were included (73% men, mean age 53 yrs, mean BASDAI 3.0). Interobserver and intraobserver ICC of the UCOASMI was 0.98. Conventional measurements showed lower but adequate reproducibility as well, except for interobserver reliability of lateral flexion (0.41), cervical rotation (0.61), and Schöber test (0.07), and intraobserver reliability of tragus-to-wall distance (0.30). Reproducibility of the UCOASMI seems very high, and apparently more reliable than conventional measures of mobility.
dc.description.versionSi
dc.identifier.citationGarrido-Castro JL, Curbelo R, Mazzucchelli R, Domínguez-González ME, Gonzalez-Navas C, Flores Robles BJ, et al. High Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis. J Rheumatol. 2018 Oct;45(10):1383-1388
dc.identifier.doi10.3899/jrheum.170941
dc.identifier.issn0315-162X
dc.identifier.pmid29907675
dc.identifier.unpaywallURLhttps://www.jrheum.org/content/jrheum/45/10/1383.full.pdf
dc.identifier.urihttp://hdl.handle.net/10668/12601
dc.issue.number10
dc.journal.titleThe Journal of rheumatology
dc.journal.titleabbreviationJ Rheumatol
dc.language.isoen
dc.organizationInstituto Maimónides de Investigación Biomédica de Córdoba-IMIBIC
dc.organizationHospital Universitario Reina Sofía
dc.page.number1383-1388
dc.publisherJournal of Rheumatology Publishing
dc.pubmedtypeJournal Article
dc.pubmedtypeObservational Study
dc.pubmedtypeResearch Support, Non-U.S. Gov't
dc.relation.publisherversionhttps://www.jrheum.org/content/45/10/1383.long
dc.rights.accessRightsopen access
dc.subjectOutcome assessment
dc.subjectSpine
dc.subjectSpondyloarthropathy
dc.subject.decsColumna vertebral
dc.subject.decsEspondilitis anquilosante
dc.subject.decsImagenología tridimensional
dc.subject.decsRango del movimiento articular
dc.subject.decsReproducibilidad de los resultados
dc.subject.decsVariaciones dependientes del observador
dc.subject.decsÍndice de severidad de la enfermedad
dc.subject.meshActivities of daily living
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshFemale
dc.subject.meshFollow-up studies
dc.subject.meshHealth surveys
dc.subject.meshHumans
dc.subject.meshImaging, three-dimensional
dc.subject.meshMale
dc.subject.meshMiddle aged
dc.subject.meshObserver variation
dc.subject.meshRange of motion, articular
dc.subject.meshReproducibility of results
dc.subject.meshSeverity of illness index
dc.subject.meshSpine
dc.subject.meshSpondylitis, ankylosing
dc.titleHigh Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number45
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RISalud_Accesorestringido.pdf
Size:
93.39 KB
Format: