Abstract

Concerns about the prognostic value of NYHA functional class (FC) in heart failure (HF) patients carrying a prophylactic implantable cardioverter defibrillator (ICD) are still present. We aimed to compare whether mortality and arrhythmic risk were different, in a cohort of HF patients undergoing ICD-only implant, according to their FC. HF patients with left ventricle ejection fraction (LVEF) ≤35%, undergoing first prophylactic ICD-only implant were collected from a multicentre nationwide registry (2006-2015). Six hundred and twenty-one patients were identified (101 patients in NYHA I; 411 in NYHA II; 109 in NYHA III). After a mean follow-up of 4.4 years (±2.1), 126 patients died (20.3%). All-cause mortality risk was higher in symptomatic patients: 13.9% in NYHA I patients, 18.3% in NYHA II patients (HR: 1.8, 95% CI 1.1-3.2), and 32.9% in NYHA III patients (HR: 3.9, 95% CI 2.1-7.3). Seventy-eight out of all deaths were due to cardiovascular causes (12.6%). Cardiovascular mortality risk was also higher in symptomatic patients: 6.9% in NYHA I patients, 11% in NYHA II patients (HR: 2.2, 95% CI 1.1-4.9), and 23.9% in NYHA III (HR: 5.5, 95% CI 2.4-12.7). One hundred and seventeen patients received a first appropriate ICD therapy (19.4%). Arrhythmia free survival did not differ among study groups [20.8% in NYHA I patients, 18.7% in NYHA II (HR: 1.1, 95% CI 0.6-1.7) and 20.8% in NYHA III patients (HR: 1.3, 95% CI 0.7-2.5)]. NYHA class independently predicted cardiovascular mortality (NYHA III vs. NYHA I: HR, 4.7; 95% CI, 1.7-12.8, P = 0.002; NYHA II vs. NYHA I: HR, 2.1, 95% CI, 1.0-5.6, P = 0.05) but not all-cause death (NYHA III vs. NYHA I: HR: 1.8, 95% CI 0.8-3.9, P = 0.11; NYHA II vs. NYHA I: HR, 1.1, 95% CI 0.6-2.2, P = 0.71;). Atrial fibrillation, chronic kidney disease, and diabetes emerged as predictors of both all-cause death [(HR: 1.8, 95% CI 1.2-2.8, P = 0.005), (HR: 2.2, 95% CI 1.4-3.4, P Mortality in HF patients undergoing prophylactic ICD implantation was higher in symptomatic patients. NYHA functional class along with other comorbidities might be helpful to identify a subgroup of ICD carriers with poorer prognosis and higher risk of cardiovascular death.

Description

MeSH Terms

Cause of Death
Death, Sudden, Cardiac
Defibrillators, Implantable
Female
Follow-Up Studies
Heart Failure
Humans
Incidence
Male
Middle Aged
Primary Prevention
Prognosis
Retrospective Studies
Risk Factors
Spain
Stroke Volume

DeCS Terms

CIE Terms

Keywords

Implantable cardioverter defibrillator, NYHA functional class, Prognosis

Citation