Publication:
Anterior pre-tensioned external fixator for pelvic fractures and dislocations. Initial clinical series

dc.contributor.authorQueipo-de-Llano, A.
dc.contributor.authorLombardo-Torre, M.
dc.contributor.authorLeiva-Gea, A.
dc.contributor.authorDelgado-Rufino, F. B.
dc.contributor.authorLuna-Gonzalez, F.
dc.contributor.authoraffiliation[Queipo-de-Llano, A.] Hosp Univ Virgen Victoria, Serv Cirugia Ortoped & Traumatol, 4th Floor,Campus Teatinos S-N, Malaga 29010, Spain
dc.contributor.authoraffiliation[Lombardo-Torre, M.] Hosp Univ Virgen Victoria, Serv Cirugia Ortoped & Traumatol, 4th Floor,Campus Teatinos S-N, Malaga 29010, Spain
dc.contributor.authoraffiliation[Leiva-Gea, A.] Hosp Univ Virgen Victoria, Serv Cirugia Ortoped & Traumatol, 4th Floor,Campus Teatinos S-N, Malaga 29010, Spain
dc.contributor.authoraffiliation[Delgado-Rufino, F. B.] Hosp Univ Virgen Victoria, Serv Cirugia Ortoped & Traumatol, 4th Floor,Campus Teatinos S-N, Malaga 29010, Spain
dc.contributor.authoraffiliation[Luna-Gonzalez, F.] Hosp Univ Virgen Victoria, Serv Cirugia Ortoped & Traumatol, 4th Floor,Campus Teatinos S-N, Malaga 29010, Spain
dc.date.accessioned2023-02-12T02:21:05Z
dc.date.available2023-02-12T02:21:05Z
dc.date.issued2016-12-01
dc.description.abstractIn the treatment of unstable pelvic ring fractures, external fixators have the limitation of not adequately stabilizing the injured posterior elements. This article presents a novel and simple technique of temporary external fixation of the pelvic ring, able to produce compression of both the anterior and posterior pelvic elements. A curved flexible carbon-fiber rod is used, pre-tensioned before attachment to supra-acetabular Schanz screws. Although more extensive clinical experience is required, favorable preliminary results in a series of 13 patients with unstable pelvic fracture were encouraging: the aim of closing the posterior and anterior elements of the pelvic ring was achieved in all cases treated with this technique, and 12 patients survived. Radiological results were excellent in 3 cases and good in 9 cases. No major complications, such as secondary displacement, vertical re-displacement or deep infection, were observed. Mean operative time was 25 min, compatible with emergency management. (C) 2016 Elsevier Masson SAS. All rights reserved.
dc.identifier.doi10.1016/j.otsr.2016.09.013
dc.identifier.issn1877-0568
dc.identifier.unpaywallURLhttps://doi.org/10.1016/j.otsr.2016.09.013
dc.identifier.urihttp://hdl.handle.net/10668/18862
dc.identifier.wosID389540700025
dc.issue.number8
dc.journal.titleOrthopaedics & traumatology-surgery & research
dc.journal.titleabbreviationOrthop. traumatol.-surg. res.
dc.language.isoen
dc.organizationHospital Universitario Virgen de la Victoria
dc.page.number1103-1108
dc.publisherElsevier masson
dc.rights.accessRightsopen access
dc.subjectPelvis fracture
dc.subjectUrgent stabilization
dc.subjectPelvic compression
dc.subjectExternal fixation
dc.subjectPre -tensed bar
dc.subjectRing injuries
dc.subjectCompression
dc.subjectStabilization
dc.subjectGirdle
dc.titleAnterior pre-tensioned external fixator for pelvic fractures and dislocations. Initial clinical series
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number102
dc.wostypeArticle
dspace.entity.typePublication

Files