Publication:
Comparison between urine culture profile and morphology classification using fluorescence parameters of the Sysmex UF-1000i urine flow cytometer.

dc.contributor.authorJiménez-Guerra, G
dc.contributor.authorHeras-Cañas, V
dc.contributor.authorValera-Arcas, M D
dc.contributor.authorRodríguez-Grangér, J
dc.contributor.authorNavarro, J M
dc.contributor.authorGutiérrez-Fernández, J
dc.date.accessioned2023-01-25T09:42:21Z
dc.date.available2023-01-25T09:42:21Z
dc.date.issued2017-01-04
dc.description.abstractTo determine the usefulness of the fluorescence parameters generated by Sysmex UF-1000i flow cytometer for the rapid diagnosis of urinary tract infection by bacilli or cocci. Urine samples (n = 1924) were studied by culture and microbiology and subsequently by cytometry, using BACT-Morph software and considering forward-scattered light (FSC) and fluorescent light scatter fluorescence parameters. BACT-Morph software showed moderate diagnostic accuracy (78·4%) to detect rod-shaped bacteria, with sensitivity of 82·4% and specificity of 62·5%. Forward-scattered (B_FSC) values of the bacterial channel were significant higher for the Gram-positive cocci category (P  Utilization of BACT-Morph software and bacterial channel fluorescence parameters (B_FSC ≥24·2 ch) offered an approximate discrimination of bacilli and cocci but the specificity was low, especially for FSC. Further research is needed to establish the usefulness of flow cytometry for aetiological diagnosis.
dc.identifier.doi10.1111/jam.13354
dc.identifier.essn1365-2672
dc.identifier.pmid27860075
dc.identifier.unpaywallURLhttps://sfamjournals.onlinelibrary.wiley.com/doi/pdfdirect/10.1111/jam.13354
dc.identifier.urihttp://hdl.handle.net/10668/10614
dc.issue.number2
dc.journal.titleJournal of applied microbiology
dc.journal.titleabbreviationJ Appl Microbiol
dc.language.isoen
dc.organizationHospital Universitario Virgen de las Nieves
dc.page.number473-480
dc.pubmedtypeComparative Study
dc.pubmedtypeJournal Article
dc.rights.accessRightsopen access
dc.subjectdiagnosis
dc.subjectfluorescence
dc.subjecturinary tract infection
dc.subjecturine culture
dc.subjecturine flow cytometer
dc.subject.meshColoring Agents
dc.subject.meshFemale
dc.subject.meshFlow Cytometry
dc.subject.meshFluorescence
dc.subject.meshHumans
dc.subject.meshHypersensitivity
dc.subject.meshLight
dc.subject.meshMale
dc.subject.meshSensitivity and Specificity
dc.subject.meshSoftware
dc.subject.meshUrinalysis
dc.subject.meshUrinary Tract Infections
dc.subject.meshUrine
dc.titleComparison between urine culture profile and morphology classification using fluorescence parameters of the Sysmex UF-1000i urine flow cytometer.
dc.typeresearch article
dc.type.hasVersionVoR
dc.volume.number122
dspace.entity.typePublication