Publication: Improved passive catheter tracking with positive contrast for CMR-guided cardiac catheterization using partial saturation (pSAT).
Loading...
Identifiers
Date
2017-08-15
Authors
Velasco Forte, Mari Nieves
Pushparajah, Kuberan
Schaeffter, Tobias
Valverde Perez, Israel
Rhode, Kawal
Ruijsink, Bram
Alhrishy, Mazen
Byrne, Nicholas
Chiribiri, Amedeo
Ismail, Tevfik
Advisors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Cardiac catheterization is a common procedure in patients with congenital heart disease (CHD). Although cardiovascular magnetic resonance imaging (CMR) represents a promising alternative approach to fluoroscopy guidance, simultaneous high contrast visualization of catheter, soft tissue and the blood pool remains challenging. In this study, a novel passive tracking technique is proposed for enhanced positive contrast visualization of gadolinium-filled balloon catheters using partial saturation (pSAT) magnetization preparation. The proposed pSAT sequence uses a single shot acquisition with balanced steady-state free precession (bSSFP) readout preceded by a partial saturation pre-pulse. This technique was initially evaluated in five healthy subjects. The pSAT sequence was compared to conventional bSSFP images acquired with (SAT) and without (Non-SAT) saturation pre-pulse. Signal-to-noise ratio (SNR) of the catheter balloon, blood and myocardium and the corresponding contrast-to-noise ratio (CNR) are reported. Subjective assessment of image suitability for CMR-guidance and ideal pSAT angle was performed by three cardiologists. The feasibility of the pSAT sequence is demonstrated in two adult patients undergoing CMR-guided cardiac catheterization. The proposed pSAT approach provided better catheter balloon/blood contrast and catheter balloon/myocardium contrast than conventional Non-SAT sequences. It also resulted in better blood and myocardium SNR than SAT sequences. When averaged over all volunteers, images acquired with a pSAT angle of 20° to 40° enabled simultaneous visualization of the catheter balloon and the cardiovascular anatomy (blood and myocardium) and were found suitable for CMR-guidance in >93% of cases. The pSAT sequence was successfully used in two patients undergoing CMR-guided diagnostic cardiac catheterization. The proposed pSAT sequence offers real-time, simultaneous, enhanced contrast visualization of the catheter balloon, soft tissues and blood. This technique provides improved passive tracking capabilities during CMR-guided catheterization in patients.
Description
MeSH Terms
Adolescent
Adult
Cardiac Catheterization
Cardiac Catheters
Case-Control Studies
Contrast Media
Feasibility Studies
Female
Heart Defects, Congenital
Humans
Image Interpretation, Computer-Assisted
Magnetic Resonance Imaging, Interventional
Male
Meglumine
Organometallic Compounds
Predictive Value of Tests
Adult
Cardiac Catheterization
Cardiac Catheters
Case-Control Studies
Contrast Media
Feasibility Studies
Female
Heart Defects, Congenital
Humans
Image Interpretation, Computer-Assisted
Magnetic Resonance Imaging, Interventional
Male
Meglumine
Organometallic Compounds
Predictive Value of Tests
DeCS Terms
CIE Terms
Keywords
Cardiac catheterization, Congenital heart disease, Device tracking, Interventional CMR