Publication:
A comparable rate of levator ani muscle injury in operative vaginal delivery (forceps and vacuum) according to the characteristics of the instrumentation.

No Thumbnail Available

Date

2019-02-22

Authors

García-Mejido, José A
Fernández-Palacín, Ana
Bonomi Barby, María J
Castro, Laura
Aquise, Adriana
Sainz, José A

Advisors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics
Google Scholar
Export

Research Projects

Organizational Units

Journal Issue

Abstract

Forceps delivery is associated with a high rate of levator ani muscle (LAM) trauma (avulsion) at 35%-65% whereas data on avulsion rates after vacuum delivery vary greatly. Nevertheless, a common characteristic of all previous studies carried out to evaluate the association between instrumental deliveries (forceps and vacuum) and LAM avulsion, is the fact that characteristics of the instrumentation have not been described or evaluated. The objective of this study is to compare the rate of LAM avulsion between forceps and vacuum deliveries according to the characteristics of the instrumentation. Prospective, observational study, including 263 nulliparous women, who underwent an instrumental delivery with either Malmström vacuum or Kielland forceps. The characteristics of the instrumentation, position (anterior position and other position) and height of the fetal head at the moment of instrumentation (low instrumentation [vertex at +2 station] and mid-instrumentation [head is involved but leading part above +2 station]) were assessed. Evaluation of LAM avulsion was performed at 6 months postpartum by three-/four-dimensional transperineal ultrasound. Using the multi-view mode, a complete avulsion was diagnosed when the abnormal muscle insertion was identified in all three central slices, that is, in the plane of minimal hiatal dimensions and the 2.5-mm and 5.0-mm slices cranial to this one. To detect a 30% or 15% difference in the LAM injury rate, with 80% power and 5% α-error, we needed, respectively 42 and 99 women per study group. In all, 263 nulliparous individuals have been evaluated (162 vacuum deliveries, 101 forceps deliveries). Instrumentation in an occipito-anterior position was more frequent in vacuum deliveries (75.3% vs 56.4%, P = .002), whereas other positions were more frequent in the forceps deliveries group (24.7% vs 43.6%). No statistically significant differences were noted regarding the height of the fetal head at the moment of instrumentation. No statistically significant differences were found in the presence of LAM avulsion (41.4% vs 38.6%) between vacuum and forceps deliveries. The univariate analysis of the crude odds ratio was 1.17, 95% CI 0.67-1.98, P = .70 for the avulsion of the LAM and the multivariate of the adjusted OR 0.90, 95% CI; 0.53-1.55, P = .71. We consider that, in our population, LAM avulsion rate should not be a factor taken into account when choosing the type of instrumentation (Malmström vacuum or Kielland forceps) in an operative delivery.

Description

MeSH Terms

Adult
Comparative Effectiveness Research
Delivery, Obstetric
Female
Humans
Obstetric Labor Complications
Obstetrical Forceps
Outcome and Process Assessment, Health Care
Patient Selection
Pelvic Floor
Pregnancy
Risk Factors
Soft Tissue Injuries
Spain
Vacuum Extraction, Obstetrical

DeCS Terms

CIE Terms

Keywords

forceps delivery, levator ani muscle, ultrasound transperineal (three-dimensional), vacuum delivery

Citation